Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T02CM05614
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/02/2002 | JOE LINVILLE | NPPO | REVIEW | Approved | |
| 01/02/2003 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | A revised landscape plan is required for the site. The plan must include all site areas. Although the proposed expansion would not subject the property to a full review for landscape and screening compliance, any modifications to the site are to be documented on the revised landscape plan. Provide a copy of the previously approved landscape plan for reference in order to allow the review to proceed. DS 2-07.2.0 Provide calculations on the site plan as requested by the Zoning reviewer. DS 2-02.2.2.A.6 Landscape borders must be provided entirely within the property limits, unless expressly approved by the City Engineer. Provide documentation in writing of any approvals received. LUC 3.7.2.4 Landscape borders are to be located based on the MS&R right of way line. Revise the landscape plans to identify the MS&R right of way lines where applicable and dimension any portion of the right of way to be used to meet the landscape border requirements. LUC 3.7.2.4, LUC 2.8.3.5.A Canopy trees are required for vehicular use areas per LUC 3.7.2.3. Revise the plans to comply with the regulations. This requirement applies to new vehicular use area and the previously approved areas due the relocation of parking spaces. |
| 01/06/2003 | JAMES TATE | FLOODPLAIN | REVIEW | Approved | |
| 01/06/2003 | JIM TATE | ENGINEERING | REVIEW | Denied | DATE: January 6, 2003 ACTIVITY NUMBER: T02CM05614 PROJECT NAME: Precision Toyota PROJECT ADDRESS: 871 W. Roger Rd. PROJECT REVIEWER: James C. Tate, P.E. Resubmittal Required: Site Plan The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. 1. Since the same drawings are being used for Site and Grading please title them as such (Site/Grading Plan). 2. The Drainage Report sizes the catch basin as 40 sq.ft. The Site/Grading plan shows 2'X10' (20 sq.ft.) Correct. 3. Place a note on the plan that all roof downspouts will be routed under any adjacent sidewalk. Sidewalks must be flood free for up to the 10 yr. event. DS 2-08.4.1.E 4. Sidewalks must be provided along all street frontage. It is not clear on the plan whether or not there is existing sidewalk. Provide. DS 3-01.3.3.A |
| 01/06/2003 | JIM TATE | SANITATION | REVIEW | Approved | |
| 12/09/2002 | JIM EGAN | FIRE | REVIEW | Approved | |
| 12/19/2002 | DAN CASTRO | HANDICAP-SITE | REVIEW | Approved | |
| 12/19/2002 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. CODE SECTION/ DEVELOPMENT STANDARD 1. The following comments are based on a greater than 25% building area expansion (5,520 S.F. proposed; 18,863 S.F. existing) resulting in full code compliance review of the entire site. Please provide the building area, vehicular use area, and lot area expansion calculations on the plan. D.S. 2-02.2.2.A.6 2. Lot combination is required for this site. Attached is a copy of the covenant prepared by the City Attorney's Office which must be recorded and a copy submitted to the Zoning Review Section prior to site plan approval. In addition to the covenant, a copy of the Pima County Assessors Tax Combination form must also be signed and approved and a copy submitted to the Zoning Review Section. The tax combination form may be obtained at the Pima County Assessors office. D.S. 2-02.2.1.A.2 3. Note the project address. D.S. 2-02.2.1.A.3 4. Demonstrate continuous on-site pedestrian circulation from the existing building to the new building. Refer to2-08 for pedestrian circulation path requirements. D.S. 2-02.2.1.A.12 5. If applicable, provide a detail of existing and/or proposed free-standing signage and outdoor lighting on the site plan. D.S. 2-02.2.1.A.13/ D.S. 2-02.2.1.A.25 6. Label and dimension the existing and future ½ right-of-way for Fairview Road. Indicate in the response letter if any site improvements are to be located in the MS&R right-of-way. D.S. 2-02.2.1.A.19 7. All requested changes must be made to the site and landscape plans. D.S. 2-07.2.1.A |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/08/2003 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |