Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T02CM05602
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/28/2003 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Greg Carlson Engeering, LLC Greg Carlson, PE 1095 S. Houghton Road Tucson, Arizona 85701 SUBJECT: 1095 S. Tyndall Ave. Site plan T03CM05602 (First Review) T14S, R14E, Section 18 RESUBMITTAL REQUIRED: Site Plan and Drainage Statement. The Site Plan (SP) and Drainage Statement (DS) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. A separate grading permit will be required. 2. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12. 3. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. Call out the Standard COT detail number of the refuse container or provide details. 4. There is no construction allowed in the Right-of-way, this includes the landscape buffer. A private improvement agreement may be necessary for any work performed within the Right-of-way as Driveways, Sidewalks etc. Contact Department of transportation at (520) 791-4249 for permit information. 5. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers (per COT/SD) will be used when the roof scuppers locations have been designed will suffice. 6. Why are there two property lines shown at the east side of the property? Please address. 7. Add note: "Depress all landscaped areas 6" maximum for water harvesting". Drainage Statement: 1. The drainage statement is approved. If you have any questions, I can be reached at 791-5550 or pmachad2@ci.tucson.az.us Paul Machado Senior Engineering Associate, |
| 01/28/2003 | ANY | FLOODPLAIN | REVIEW | Approved | |
| 01/28/2003 | ANY | SANITATION | REVIEW | Denied | To: Greg Carlson Engeering, LLC Greg Carlson, PE 1095 S. Houghton Road Tucson, Arizona 85701 SUBJECT: 1095 S. Tyndall Ave. Site plan T03CM05602 (First Review) T14S, R14E, Section 18 RESUBMITTAL REQUIRED: Site Plan The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Sanitation: 1. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. Call out the Standard COT detail number of the refuse container or provide details. If you have any questions, I can be reached at 791-5550 or pmachad2@ci.tucson.az.us Paul Machado Senior Engineering Associate, |
| 12/06/2002 | JIM EGAN | FIRE | REVIEW | Approved | |
| 12/16/2002 | DAN CASTRO | HANDICAP-SITE | REVIEW | Denied | If the building is proposed to be habitable, ADA requirements (i.e. accessible parking and pedestrian path) apply to the site and details must be provided. Clarify by note whether the building is proposed to be habitable or not. |
| 12/16/2002 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. CODE SECTION/ DEVELOPMENT STANDARD 1. Please clarify by note on the plan, the type of storage to occur on the site. If the site is proposed for the storage of trade and/or personal goods by a business or industrial establishment, the principal land use of the site is considered "Commercial Storage " as defined in L.U.C. Sec. 6.3.11.2. If the aforementioned applies, please revise the proposed use listed under general note two (2) to the applicable use listed under L.U.C. Sec. 2.7.2.2.H, "Commercial Storage "34", subject to: Sec. 3.5.10.1 D.S. 2-02.2.1.A.31 2. Per Pima County Assessors Records, the site is comprised of two separate lots which must be combined prior to site plan approval. Attached is a copy of the covenant prepared by the City Attorney's Office which must be recorded and a copy submitted to the Zoning Review Section prior to site plan approval. In addition to the covenant, a copy of the Pima County Assessors Tax Combination form must also be signed and approved and a copy submitted to the Zoning Review Section. The tax combination form may be obtained at the Pima County Assessors office. D.S. 2-02.2.1.A.2 3. Note the maximum building height allowed. D.S. 2-02.2.1.A.6 4. Dimension the building setback to the north lot line. Minimum building setback required for a side street perimeter yard is 10 feet. 5. a) Provide the vehicle parking calculation for the proposed use as listed under L.U.C. Sec. 3.3.4 and revise general note number four (4) as required. b) If the building is proposed to be habitable, ADA requirements (i.e. accessible parking and pedestrian path) apply to the site and details must be provided. Clarify by note whether the building is proposed to be habitable or not. D.S. 2-02.2.1.A.8 6. a) Provide the bicycle parking calculation for the proposed use as listed under the L.U.C. Sec. 3.3.4. b) Provide a fully dimensioned bicycle parking space detail. Refer to D.S. 2-09 for design criteria. D.S. 2-02.2.1.A.9 7. Per L.U.C. Sec. 3.2.8.4, pedestrian facilities are required all new structures. Refer to D.S. 2-08 for location and design criteria. D.S. 2-02.2.1.A.12 8. If applicable, provide a detail of existing and/or proposed free-standing signage and outdoor lighting on the site plan. D.S. 2-02.2.1.A.13 9. Provide written approval from the Traffic Engineering Section, which allows access from an alley. Please contact Zelin Canchola at 791-4259 for information regarding alley access. 10. Add the following note: "Loading space not required for this use". D.S. 2-02.2.2.A.5 11. All requested changes must be made to the site and landscape plans. D.S. 2-07.2.1.A |
| 12/23/2002 | JOE LINVILLE | NPPO | REVIEW | Approved | Exception per 1998 PC aerial photo, prev. developed. |
| 12/23/2002 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | Revise the plans as requested by other agencies and as requested in the following comments. All landscaping and screening must comply with LUC 3.7 and DS 2-06. The proposed vehicular use area must be surfaced per LUC 3.3.7.3. Revise the plans as necessary. Barriers must be provided at the perimeter of the vehicular use area to prevent vehicles from driving or parking on unpaved portions of the site. 3-05.2.3.C Barriers must also be located such that parked vehicles will not overhang any portion the street landscape borders. DS 2-06.3.3.E The site must be screened in compliance with LUC Table 3.7.2-I which requires a minimum five foot high screen for commercial or industrial uses and a minimum 6' high screen for outdoor srorage areas. Revise the plans as appropriate. The proposal to locate code required landscaping within the adjacent right of way must be approved in writing by the City Engineer. Provide any approvals obtained with future submittals. LUC 3.7.2.4. Approval is also required for the existing fencing located in the public right of way. The refuse storage area must be screened at minimum with six-foot high masonry wall. LUC Table 3.7.2-I The on site landscaping and adjacent right of way area must be maintained in a clean condition, free of weeds and debris and as shown on the approved plans. Add note to the plan indicating that a landscape inspection will be required prior to issuance of a certificate of occupancy. LUC 3.7.7.4; 3.7.6 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/29/2003 | TAMI ACHONG | OUT TO CUSTOMER | Completed |