Permit Number: T02CM05502
Parcel: 12002041A

Address:
727 W AJO WY

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T02CM05502
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/06/2003 JIM TATE ENGINEERING REVIEW Denied A copy of the stamped approved Site Plan must be included in the submittal.
05/13/2003 PETER MCLAUGHLIN ZONING REVIEW Denied Site Plan approval required prior to building approval.
05/22/2003 LINDA BUCZYNSKI ELECTRICAL-COMMERCIAL REVIEW Denied Submit electrical plans showing exit illumination and any other electrical changes.
05/22/2003 DOUG LAAKSO BUILDING-COMMERCIAL REVIEW Denied .. T02CM05502 .. 727 W AJO ROAD .. DGL .. 5/22/02 .. SEE PRIOR COMMENTS 1,2,3,4,9, 10, 11, 12, 14, 16, 17, 18, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 35, AND , 36. PROVIDE INFORMATION REQUIRED. .............. . ....... PRIOR COMMENTS ATTACHED. ....................... ............... ... T02CM05502 .. 727 W. AJO WAY .. DGL .. 1/28/03 ........ .. 1. SEPARATE INTO TWO APPLICATIONS : ..................... .......1. SEPARATE PERMITS FOR EACH TENANT SPACE. ... .......2. COMPLETED CODE REVIEW CHECKLIST FOR EACH TENANT SPACE. .............................................................. ......3. COMPLETED COMMERCIAL PLAN SUBMITTAL CHECKLIST FOR EACH TENANT SPACE. ........................... .......4. OFFICIAL ADDRESS SLIP FOR EACH TENANT SPACE. ........................................................................... .. 2. SHOW PREMISE IDENTIFICATION ON DRAWINGS PER IBC SEC 501.2. ................................................................ .. 3. PROVIDE ADDRESSING ON DRAWINGS PER PIMA COUNTY ADDRESSING ORDINANCE. ............................... .. 4. PROVIDE ALLOWABLE AREA CALCULATION PER IBC SEC 5. ............................................................................ .. 5. DIMENSIONALLY LOCATE BUILDING ON SITE FROM TWO ADJACENT PROPERTY LINES. ................................. .. 6. PROVIDE OVERALL DIMENSIONS OF BUILDING ON DRAWINGS. .................................................................... .. 7. CLARIFY EXTERIOR WALL FIRE RATING REQUIREMENT OF SOUTH WALL OF BUILDING, REF DWG T-1, PER TABLE 601 AND 602, DIMENSION WALL/S FROM PROPERTY LINES. .......................................................... .. 8. SHOW CONFORMANCE WITH IBC CHAPTER 7, SHOULD FIRE RATINGS BE REQUIRED, PROVIDE FIRE-RATED DETAIL/S AND FIRE LISTING/S ON DRAWINGS. .................................................................... .. 9. LIST INTERIOR WALL AND CEILING FINISH REQUIREMENTS ON DRAWINGS PER IBC TABLE 803.4. .... ..10. PROVIDE ADEQUATE GRADE ELEVATIONS TO SHOW CONFORMANCE WITH IBC CHAPTERS 10, 11 & 34 AND ANSI A117.1-1998 ed, ( PATH OF TRAVEL , ie: LANDINGS, PARKING, PARKING ACCESS AISLES, RAMPS, etc. ). ........ ..11. CLARIFY EXIT ILLUMINATION PER IBC SEC 1003.2.11. ..12. CLARIFY ACCESSIBILITY PER IBC CHAPTER 11. ....... ..13. PROVIDE ARCHITECT'S DESIGN AND SEAL ON DRAWINGS S-1, S-2 AND S-3 FOR OTHER THAN STRUCTURAL. ................................................................ ..14. CLARIFY FLASHING PER IBC SEC 1405, REF DWG S-3. ..15. PROVIDE ICBO NUMBER W/ MANUFACTURER'S NAME AND MODEL NUMBER FOR ONE-COAT STUCCO SYSTEM PER IBC SEC 1405, REF DWG S-3. ...................... ..16. DIMENSIONALLY LOCATE ROOF-MOUNTED EQUIPMENT AND ADDRESS LOADING IN STRUCTURAL CALCULATIONS REF DWG S-2. ......................................... ..17. SPECIFY ROOF CLASSIFICATION PER IBC CHAPTER 15, 1505, 1506, & 1507. .................................................... ..18. INDICATE LOCATION OF SAFETY GLAZING ON DRAWINGS TO SHOW COMPLIANCE WITH IBC SEC 2406, REF DWG A-2. ................................................................ ..19. CLARIFY CONTINUOUS FOOTING @ EXTERIOR WALL, REF DWG S-1, PER INC SEC 1805.2. ................................ ..20. PROVIDE CONSTRUCTION DOCUMENTS COMPLYING WITH IBC SEC 1603, 1901.4 & 2101.3. .............................. ..21. PROVIDE DESIGN PER IBC vs UBC SUBMITTED IN STRUCTURAL CALCULATIONS. ........................................ . 22. SHOW ON DWGS AND CALCULATIONS - ANCHORAGE OF ROOF DIAPHRAM/S TO MASONRY WALLS PER IBC SEC 1604.8. ........................................................................... . 23. PROVIDE CALCULATIONS ADDRESSING CONNECTIONS OF NEW CONSTRUCTION TO EXISTING. ... . 24. CLARIFY WOOD STUDS USED THROUGH-OUT OR CLEARLY DETAIL ON DRAWINGS MATERIALS ( METAL STUDS ), REF DWG S-3 AND CALCULATIONS. .................. . 25. CLARIFY SHEAR WALL/TRANSFER OF SHEAR AT NORTH ELEVATION REF DWG A-2 AND CALCULATIONS. .. . 26. PROVIDE SKETCHES IN STRUCTURAL CALCULATIONS LOCATING MEMBERS AND SYSTEMS ( SHEAR WALLS ) DESIGNED, PER 1994 UAC SEC 302. ..... . 27. PROVIDE CALCULATIONS AND SHOW DETAILS FOR MECHANICAL UNITS ON ROOF, INCLUDING WEIGHTS, ON ROOF PLAN W/ LOCATIONS. ............................................ . 28. DETAILS AND CALCULATIONS REQUIRED FOR STOREFRONT COLUMNS/BEAM LINES INCLUDING WALL ABOVE. ........................................................................... . 29. FULLY DETAIL SHEAR WALLS. ................................ . 30. DETAIL ROOF DIAPHAGM/S ON DRAWINGS. ............ . 31. PROVIDE CALCULATIONS FOR JOIST TO WALL CONNECTIONS, REF 7/S-3, 13/S-3 & 16/S-3. .................... . 32. PROVIDE DETAILS FOR ROOF DRAINS. .................. . 33. SUBMIT SHOP DRAWINGS FOR TRUSSES. .............. . 34. SEPARATE PERMIT REQUIRED FOR SIGNS. ............. . FOLLOWING COMMENTS INADVERTANTLY LEFT OFF THIS LISTING ON COMPUTER ORIGINALLY . . 35. INSPECTION PROGRAM REQUIRED PER UAC SEC 302.5 FOR : EPOXY ANCHORS. ....................................... . 36. PROVIDE MATERIAL SPECIFICATIONS ON DRAWINGS. ........................................................ ........... . 37. SEPARATE PERMITS REQUIRED FOR TENANT IMPROVEMENTS/OCCUPANCY.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/27/2003 MONICA VALDEZ OUT TO CUSTOMER Completed
05/23/2003 ANGIE SHOFFSTALL REJECT SHELF Completed