Review Date Reviewer's Name Type of Review Description Status Comments
05/16/2003 RAUL PALMA BUILDING-COMMERCIAL REVIEW Denied City of Tucson, Development Services
BUILDING AND STRUCTURAL COMMENTS
1. Provide proof of compliance with section 2407. ( Glazing in railing-in-fill panels shall conform
to ANSI Z 97.1 listed in chapter 35 of the IBC 2000).
2. The fax sheet no. P003, at bottom of sheet, specifies that the tests were performed under a diff-
erent code and the safety factor was ignored, therefore another test under the current code would
3 Show a detail connection of escalator to structure and cross referance.
4 Specify the number of bolts and size, or the size of weld and length as per engineering design.