Permit Number: T02CM05370
Parcel: 106030720

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T02CM05370
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/13/2003 BLANCA ESPINO ENGINEERING REVIEW Denied Site Plan
1. Comment not addressed. Indicate property description on site plan sheet A2. D.S. 2-02.2.1.2

2. Comment not addressed. Indicate proposed buildings and structures, including size, roof slope and downspouts. Indicate sidewalk scuppers and dimensioned details. D.S. 2-02.2.1.6

3. Sight visibility triangles are written in pencil. All text and drawings are required to be in ink. Correct and revise. D.S. 2-02.2.1.10

4. Indicate location, type, size and height of existing and proposed signage if applicable or not. Indicate with a note on site plan. D.S. 2-02.2.1.13

5. Indicate limits of the 100-year water surface elevation on site plan. D.S. 2-02.2.1.15

6. Comment not addressed. Indicate which datum is being used for elevations. Indicate drainage patterns on site plan or submit Drainage Report. Indicate proposed finish floor elevation(s) that correspond with the approved FUP#T02OT00170 FFE. Indicate the FFE on the site/grading plan. Indicate finish grades. The grading plan indicates the main FFE to be 2340.07'. The FFE as per the approved FUP is 2334.37'. That is a difference of 5.7'. Correct and revise. D.S. 2-02.2.1.16

7. Submit a grading plan application for a grading review. D.S. 2-02.2.1.17

8. Comment not addressed. Indicate if streets are "Public or Private" on site plan. D.S. 2-02.2.1.18

9. Comment not addressed. Indicate dimensioned right-of-way. D.S. 2-02.2.1.19

10. Comment not addressed. Refuse containers in alleys require prior authorization from Solid Waste Dept. Contact John Clark at 791-3175. D.S. 2-02.2.1.32

11. Comment not addressed. Indicate issuance of Floodplain Use Permit # T02OT00170 on site plan.
07/07/2003 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond
07/08/2003 DAVID RIVERA ZONING REVIEW Approved
07/11/2003 DAVID RIVERA HANDICAP-SITE REVIEW Approved
07/14/2003 JOE LINVILLE NPPO REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
07/23/2003 MONICA VALDEZ OUT TO CUSTOMER Completed
07/15/2003 ANGIE SHOFFSTALL REJECT SHELF Completed