Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T02CM05317
Parcel: 126130200

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T02CM05317
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/24/2003 CRAIG GROSS LANDSCAPE REVIEW Approved
01/24/2003 CRAIG GROSS HANDICAP-SITE REVIEW Approved
01/29/2003 JIM TATE ENGINEERING REVIEW Denied ACTIVITY NUMBER: T02CM05317 DATE: January 29, 2003
PROJECT NAME: Midtown Plaza
PROJECT ADDRESS: 4590 E. Broadway
PROJECT REVIEWER: James C. Tate, P.E.

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: SITE PLAN, DRAINAGE REPORT (for records)

Site Plan

1. Show the existing and future sight-visibilty triangles for the corner of Broadway and Venice. There are two triangles at this corner. The triangle along Broadway should measure 340 ft. (local to arterial, near side dimension. The triangle along Venice should measure 110 ft. (arterial to local, far side dimension. The triangle on the submitted plan was not drawn from point of curb and the dimensions are incorrect. Correct.
DS 2-02.2.1.A.10

2. Provide sidewalk along the entire street frontage on Venice. The proposed plan shows curb. DS 2-02.2.1.A.21 and DS 3-01.3.3

3. Provide a note stating that elevation and drainage information is on Grading Plan sheet 1.

Drainage Report

1. The Drainage Report is acceptable for approval. Please provide two copies with the next Site Plan submittal.
01/29/2003 JIM TATE SANITATION REVIEW Approved
01/29/2003 JIM TATE FLOODPLAIN REVIEW Approved
02/10/2003 DAN CASTRO ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
03/04/2003 ELAINE ROSE OUT TO CUSTOMER Completed