Permit Review Detail
Review Status: Stopped
Review Details: SITE
Permit Number - T02CM05208
Review Name: SITE
Review Status: Stopped
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/04/2003 | ANY | ENGINEERING | REVIEW | Denied | To: 3D Architectural Designs Frank Rendon 7660 E. Lakeside Drive. Tucson, Arizona 85741 SUBJECT: Street Address Site plan T02CM05208 (First Review) T14S, R13E, Section 36 RESUBMITTAL REQUIRED: Site Plan. The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. This project was reviewed for full code compliance. 2. Please provide property description per D.S. 2-02.2.1.3. 3. Provide all existing and proposed buildings and structures, including location, size, height, overhangs, canopies, and use per D.S. 2-02.2.1.6. It is unclear what is existing and what is proposed. 4. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. 5. Show all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11. 6. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12. 7. Fully-dimensioned loading space(s) and maneuvering area(s) per D.S. 2-02.2.1.14. 8. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16. 9. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. 10. Please show dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19. 11. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. 12. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. 13. Show all fences, walls, or vegetation for screening and sight visibility by type, material, height, location and spacing per D.S. 2-02.2.1.27. 14. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. 15. Please provide adjacent property grades for review in accordance with in 2000 IBC section 13 concerning fills. 16. A private improvement agreement or permit will be necessary for any work performed within the Right-of-way. Contact Department of transportation at (520) 791-4249 for permit information. 17. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable. 18. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers (per COT/SD) will be used when the roof scuppers locations have been designed will suffice. 19. List the consulting engineer and the owner/developer on the plans with the pertinent information. 20. The property is in a balanced Basin, therefore it is subject to the Retention/Detention requirements per P.C.D.O.T. Stormwater Dentention/Retention Manual. 21. Add note: "Depress all landscaped areas 6" maximum for water harvesting". Drainage Report: 1. A Drainage report is required for parcel any subject to Detention requirdments per S.M.D.D.F.M., chap. II, 2.1.1. 2. Show the project address on the cover of the Drainage report. If you have any questions, I can be reached at 791-5550 x1193 or pmachad2@ci.tucson.az.us Paul Machado Senior Engineering Associate |
| 03/05/2003 | JIM EGAN | FIRE | REVIEW | Approved | |
| 03/12/2003 | DAN CASTRO | HANDICAP-SITE | REVIEW | Passed | |
| 03/12/2003 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. CODE SECTION/ DEVELOPMENT STANDARD 1. Per L.U.C. Sec. 3.2.3.1.C development designator "K", the maximum allowed number of units for this property is two (2). There are seven (7) existing units. 2. Per L.U.C. Sec. 3.2.6.4 Perimeter Yard "BB", the minimum building setback required from the west lot line to buildings 1 and 2 is 10 feet. The minimum building setback required from the south lot line to building 2 is 12 feet 7 inches. The minimum building setback required from the east lot line to building 1 is 12.75 feet and to building 2 is 15.56 feet. D.S. 2-02.2.1.A.7 3. Revise the vehicle parking calculation to be based on L.U.C. Sec. 3.3.4 Residential Use Group "Multifamily Dwellings 0-70 units/acre". In addition, please note the number of bedrooms for each unit and the square footage of each unit under the parking calculation. D.S. 2-02.2.1A.8 4. Revise the bicycle parking calculation to be based on the correct number of vehicle parking spaces required. D.S. 2-02.2.1.A.9 5. On-site pedestrian facilities are required per L.U.C. Sec. 3.2.8.4.B. D.S. 2-02.2.1.A.12 6. Label and dimension the existing right-of-way for Palmdale Street. D.S. 2-02.2.1.A.19 |
| 03/14/2003 | ANY | SANITATION | REVIEW | Denied | See engineering folder. |
| 03/14/2003 | ELIZABETH EBERBACH | FLOODPLAIN | REVIEW | Denied | To: 3D Architectural Designs Frank Rendon 7660 E. Lakeside Drive. Tucson, Arizona 85741 SUBJECT: Street Address Site plan T02CM05208 (First Review) T14S, R13E, Section 36 RESUBMITTAL REQUIRED: Site plan Drainage Report: 1. A Drainage report is required for parcel any subject to Detention requirdments per S.M.D.D.F.M., chap. II, 2.1.1. 2. Show the project address on the cover of the Drainage report. If you have any questions, I can be reached at 791-5550 x1193 or pmachad2@ci.tucson.az.us Paul Machado Senior Engineering Associate |
| 03/20/2003 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) A ten foot wide street landscape border is required. LUC Table 3.7.2-I 2) Any parking areas are to be screened from adjacent streets and adjacent residential uses per LUC Table 3.7.2-I. 3) The refuse storage area may not be located within the street landscape border area. The refuse storage must be buffered from the street with landscaping per LUC Table 3.7.2-I. 4) The refuse storage area must be screened from the street and adjacent residential property with a 6' high masonry wall. LUC Table 3.7.2-I 5) The parking area is to include canopy trees per LUC 3.7.2.3.A 6) Interior landscape borders are required along the east and west propety lines per LUC 3.7.2.4.B |
| 03/20/2003 | JOE LINVILLE | NPPO | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/21/2003 | ELAINE ROSE | OUT TO CUSTOMER | Stop |