Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE
Permit Number - T02CM05106
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/28/2003 | DAN CASTRO | ZONING | REVIEW | Approved | |
| 01/28/2003 | DAN CASTRO | HANDICAP-SITE | REVIEW | Approved | |
| 02/24/2003 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 02/26/2003 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | Under the Native Plant Inventory Methology a minimum of thirty percent of the viable protected native plant of each species must be preserved-in-place(PIP) or transplanted-on-site(TOS). Revise the landscape and NPPO notes and drawings as necessary to comply with the regulation and for consistency. LUC 3.8.6.2.A |
| 02/26/2003 | JOE LINVILLE | NPPO | REVIEW | Denied | Under the Native Plant Inventory Methology a minimum of thirty percent of the viable protected native plant of each species must be preserved-in-place(PIP) or transplanted-on-site(TOS). Revise the landscape and NPPO notes and drawings as necessary to comply with the regulation and for consistency. LUC 3.8.6.2.A |
| 02/27/2003 | GERRY KOZIOL | WWM | REVIEW | Passed | |
| 03/10/2003 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | To: Norm Amy IDC/Architects 2980 E. Fort Lowell Rd. Tucson, Az. 85712 SUBJECT: 1204 N. Winstel Ave Site plan T02CM05106 (Second Review) T14S, R14E, Section 04 RESUBMITTAL REQUIRED: Site Plan. The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Show refuse container location, size, and access thereto fully dimensioned and/or provide agreement per note on the plans per D.S. 2-02.2.1.32 and D.S. 6-01.0. The agreement for the use of roll-outs is to be from Solid waste. My apologies. Since my comment was not clear. Solid waste can be contacted at 791-3175. 2. Please provide adjacent property grades for review in accordance with in 2000 IBC section 13 concerning fills. 3. A private improvement agreement or permit will be necessary for any work performed within the Right-of-way. Contact Department of transportation at (520) 791-4249 for permit information. The permit is for the D/W, wheelchair ramps etc. Vertical curbs are required in the R/W. If you have any questions, I can be reached at 791-5550 or pmachad2@ci.tucson.az.us Paul Machado Senior Engineering Associate, |
| 03/10/2003 | ANY | SANITATION | REVIEW | Approved | To: Norm Amy IDC/Architects 2980 E. Fort Lowell Rd. Tucson, Az. 85712 SUBJECT: 1204 N. Winstel Ave Site plan T02CM05106 (Second Review) T14S, R14E, Section 04 RESUBMITTAL REQUIRED: Site Plan. The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Show refuse container location, size, and access thereto fully dimensioned and/or provide agreement per note on the plans per D.S. 2-02.2.1.32 and D.S. 6-01.0. The agreement for the use of roll-outs is to be from Solid waste. Since my comment was not clear, my apologies. Solid waste can be contacted at 791-3175. If you have any questions, I can be reached at 791-5550 or pmachad2@ci.tucson.az.us Paul Machado Senior Engineering Associate, |
| 03/10/2003 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | To: Norm Amy IDC/Architects 2980 E. Fort Lowell Rd. Tucson, Az. 85712 SUBJECT: 1204 N. Winstel Ave Site plan T02CM05106 (Second Review) T14S, R14E, Section 04 RESUBMITTAL REQUIRED: None Site Plan: All comments have been addressed. The site plan is approved. If you have any questions, I can be reached at 791-5550 or pmachad2@ci.tucson.az.us Paul Machado Senior Engineering Associate, |
| 03/10/2003 | ANY | SANITATION | REVIEW | Approved | To: Norm Amy IDC/Architects 2980 E. Fort Lowell Rd. Tucson, Az. 85712 SUBJECT: 1204 N. Winstel Ave Site plan T02CM05106 (Second Review) T14S, R14E, Section 04 RESUBMITTAL REQUIRED: None Site Plan: All comments have been addressed. The site plan is approved. If you have any questions, I can be reached at 791-5550 or pmachad2@ci.tucson.az.us Paul Machado Senior Engineering Associate |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/12/2003 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |