Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD
Permit Number - T02CM05074
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/01/2002 | DAN CASTRO | ZONING | REVIEW | Approved | |
| 11/01/2002 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Approved | |
| 11/01/2002 | DAN CASTRO | NPPO | REVIEW | Passed | |
| 12/09/2002 | REYES ARVAYO | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T02CM05074 PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. SITE PLAN: 1. INDICATE THE LOCATION OF GAS, WATER, ELECTRIC AND SEWER LINE ON THE PROPERTY, AND WHERE THEY ENTER THE BUILDING. PROVIDE THE LOCATION OF YOUR WATER AND GAS METER FLOOR PLAN 1. WINDOWS WITHIN 24" OF A DOOR SHALL HAVE SAFETY GLASS. FOUNDATION PLANS: 1. BOTTOM PLATE ANCHOR BOLTS LAYOUT AND SIZE? 2. DETAIL BOTTOM PLATE CONNECTION PER IRC TABLE R603.3.1 STRUCTURAL 1. SPECIFY DESIGN CRITERIA ON PLANS. VALUES FOR , ROOF DEAD LOAD AND LIVE LOAD. 2. LOAD BEARING STUDS SHALL BE DIRECTLY IN-LINE WITH RAFTERS. PER IRC 603.1.2 3. INDICATE SIZE OF METAL STUDS - MEMBER DESIGNATION. PER IRC TABLE R603.21 ELEVATIONS: 1. ELEVATION DOESN'T MATCH FLOOR PLAN ON 2'8" CORNER BRACE PANELD?? MECHANICAL PLANS: 1. THE DWELLING MUST BE PROVIDED WITH HEATING CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF 68 DEGREES AT A POINT 3' ABOVE THE FLOOR PER R303.6. INDICATE LOCATION OF BASE BOARD HEATERS ELECTRICAL PLANS: 1. NOTE ON DRAWINGS THAT ALL EXISTING BEDROOMS AND COMMON AREAS MUST HAVE SMOKE ALARMS- BATTERY OPERATED OK. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: REYES ARVAYO @ 791-5550 EXT. 1113 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/10/2002 | TAMI ACHONG | OUT TO CUSTOMER | Completed |