Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD
Permit Number - T02CM04983
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/28/2002 | PETER MCLAUGHLIN | ZONING | REVIEW | Approved | |
| 10/28/2002 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Approved | |
| 11/08/2002 | TERRY STEVENS | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T02CM04983 11/08/02 PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. GENERAL REQUIREMENTS: 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FOUNDATION PLANS: 1. DIMENSION THE DEPTH INTO UNDISTURBED SOIL FOR EACH FOOTING TYPE AND CONDITION PER TABLE R403.1.--------------MIN. 12" BELOW NATURAL GRADE WHICH WOULD BE BELOW GRANULAR FILL STRUCTURAL PLANS: 1. DOUBLE 2X8 BOX BEAM SPANNING 16' FOR PLANT LEDGE IS INADEQUATE. CHANGE OR SUBMIT CALCS. 2. LEDGER CONNECTIONS PORCH TO WALL INADEQUATE WITH 12d NAILS. PROVIDE POSITIVE CONNECTION REQUIRED. LAGS, CLIPS, ETC.-------ALSO 2X4 LEDGERS AT PLANT LEDGE 3. HANGER TYPES AND SIZES FOR RAFTERS MISSING AT PORCH AND PLANT LEDGE LEDGERS. ELEVATIONS: 1. SHOW CALCULATION OF ATTIC VENTILATION AREA IN COMPLIANCE WITH R806.2. NOTE LOCATION OF ALL VENTS NEEDED TO COMPLY.---------ASPHALT SHINGLES REQUIRE A VENTED ATTIC SPACE IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: TERRY STEVENS @ 791-5550 EXT. 1112 |
| 11/08/2002 | PETER MCLAUGHLIN | NPPO | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/15/2002 | TAMI ACHONG | OUT TO CUSTOMER | Completed |