Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T02CM04766
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/14/2002 | JIM EGAN | FIRE | REVIEW | Approved | |
| 10/14/2002 | ANY | FLOODPLAIN | REVIEW | Approved | |
| 10/14/2002 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 10/15/2002 | HOLLY PEARCE | PLUMBING-COMMERCIAL | REVIEW | Denied | Plumbing UPC1994Az.Code being used. 1. Provide a complete waste line ismetric drawing of all new waste lines. 2. Provide four RPPB assm. for P-106, 107, 109 and 110. 3.Provide condensate lines, size and discharge location on the plans. |
| 10/15/2002 | HOLLY PEARCE | WATER | REVIEW | Denied | Plumbing plans will need to be replaced. |
| 10/15/2002 | HOLLY PEARCE | MECHANICAL-COMMERCIAL | REVIEW | Denied | Mechanical IMC2000 being used. 1.Provide the manufactures name and listing for the Type I hoods on the plans. 2. Detail 12/A7.1 is incorrect and incomplete. A one hour ceiling is required over and 18" around all sides of the hoods. Shaft enclosure shall be one hour per IBC2000. NOTE: 6" of air space is required between the duct and shaft wall. |
| 10/31/2002 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | ..T02CM04766 ....4187 N. ORACLE ROAD ...DGL ...10/31/02 1. PROVIDE CONNECTION AND BRACING DETAILS, INCLUDING FASTENERS W/ TYPE, SIZE SPACING/ NUMBER, REF. DETAIL 10/A7.0 . . ................................. .. 2. PROVIDE STRUCTURAL CALCULATIONS FOR NEW PARAPETS, REF. DETAILS 10/ A7.1, 11/ A7.1, BY STRUCTURAL ENGINEER W/ SEALED AND SIGNED DRAWINGS AND CALCULATIONS. ............ ... .... .... .... 3. PROVIDE STRUCTURAL DETAILS AND DESIGN CALCULATIONS FOR EXHAUST HOOD 12/ A7.1. ............. .. 4. FULLY DETAIL AND DOCUMENT OPTION/S AT CHASE 12/ A7.1, REF. IBC, PROVIDE COPY OF LISTING FOR FIRE-RATING ON DRAWINGS. . ................................ ..... . 5. CLAIRFY DOOR SWING AT DOOR BETWEEN ROOM #108 AND ROOM #107, SWING IN DIRECTION OF EGRESS TO EXTERIOR EXIT DOOR FROM ROOM # 108. . ......... . ... 6. PROVIDE MANUFACTURER'S NAME AND MODEL NUMBER FOR CEILING, REF. NOTE #3 ON DWG. A3.0 OR FULLY DETAIL INCLUDING WIRE TIE AND CONNECTIONS TO EXISTING, etc. , REF. 3/A7.1. . .. ... ....... ............. ... .. 7. SHOW ADDRESS ON BUILDING ELEVATION/S PER PIMA COUNTY ADDRESSING ORDINANCE , SEE ATTACHMENT, REF. A5.0 , A5.1. . ................... .......... . ... |
| 11/01/2002 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 11/04/2002 | BOB SUBA | ELECTRICAL-COMMERCIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/14/2002 | DELMA ROBEY | OUT TO CUSTOMER | Completed |