Review Date Reviewer's Name Type of Review Description Status Comments
09/26/2002 PETER MCLAUGHLIN ZONING REVIEW Approved
09/26/2002 PETER MCLAUGHLIN NPPO REVIEW Passed
09/26/2002 BLANCA ESPINO FLOODPLAIN REVIEW Approved
10/29/2002 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T02CM04413

10/29/02 1816 E. SENECA

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

FLOOR PLANS:

1. DETAIL AND SPECIFY STAIR WIDTH (MINIMUM 36"), RISE AND RUN (MINIMUM 10" TREAD DEPTH AND 7 ¾"
MAXIMUM RISER HEIGHT PER R314), LANDING WIDTH (PER R312), HANDRAIL HEIGHTS (PER R315).

STRUCTURAL PLANS

1. IDENTIFY THE LEDGER/STUD CONNECTION IN 112/S2.

2. PROVIDE STAIRWAY CONNECTION DETAILS AND STRINGER SIZES. PRE-FABRICATED METAL STAIR SHALL
HAVE MANUFACTURER'S SPECIFICATIONS ATTACHED TO PLANS.

PLUMBING PLANS:

1. PROVIDE A FLOOR DRAIN AND TRAP PRIMER, SEE THE MECHANICAL DRAWING.

2. PROVIDE PRESSURE AND TEMPERATURE RELIEF VALVE AT WATER HEATER. CLARIFY, WITHOUT USING THE EJECTOR SUMP.

ELECTRICAL PLANS:

1. THE LIGHT OVER THE TUB IS REQUIRED TO BE LISTED FOR USE AS APPROVED FOR USE IN A WET AREA. PLEASE NOTE.

2. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING ONLY APPROVED
OUTLET BOXES SHALL BE USED, PER E4001.6.

3. PLEASE NOTE THAT THE EXISTING SLEEPING AREAS ARE REQUIRED TO BE PROVIDED WITH SMOKE DETECTORS. SEE R317.1.1 .





IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110
11/01/2002 GERRY KOZIOL WWM REVIEW Denied Needs design review of lift station: Robert Butcher @ 617-8206.