Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T02CM04306
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/11/2002 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T02CM04306 12/11/02 10170 E. MOUNTAIN MANOR PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. STRUCTURAL PLANS: 1. HAVE AN ENGINEER JUSTIFY THE ADEQUACY OF THE TRUSSES AND THE ABILITY OF THE EXISTING TRUSSES ABILITY TO CARRY THE ADDED LOAD. ( SEE ORIGINAL COMMENTS ) 2. PROVIDE THE SPAN OF THE TRUSSES BEARING ON THE "H3" HEADER. (SEE ORIGINAL COMMENTS ) 3. STANDARD GRADE DOUGLAS FIR IS FOR LIGHT FRAMING WHERE HIGH-STRENGTH VALUES ARE NOT REQUIRED, SUCH AS WALL FRAMING, PLATES, SILLS, CRIPPLES, BLOCKING, ETC. ALTHOUGH USED FOR RAFTERS AND JOISTS THE ENGINEER MAY BE ABLE TO JUSTIFY THIS GRADE. ELEVATIONS: 1. NOTE AND SPECIFY ROOF SLOPE. ( SEE ORIGINAL COMMENTS ) 2. SHOW CALCULATION OF ATTIC VENTILATION AREA IN COMPLIANCE WITH R806.2. NOTE LOCATION OF ALL VENTS NEEDED TO COMPLY. ( SEE ORIGINAL COMMENTS……. RE-READ R806 ABOUT THE LOCATION OF VENTILATION WHEN USING 1:300 ) 3. GLASS WITHIN 2 FT. OF A DOOR IS REQUIRED TO BE SAFETY GLASS. ELECTRICAL PLANS: 1. DELETE THE REFERENCE TO NOTES 1,3, AND 8 OR PROVIDE THE NOTES. MODEL ENERGY CODE: 1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11. 2. CALL OUT ON THE PLANS THE "U" VALUES OF THE WINDOWS AND DOORS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/12/2002 | TAMI ACHONG | OUT TO CUSTOMER | Completed |