Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T02CM04306
Parcel: 136415060

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/FLOOD

Permit Number - T02CM04306
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/20/2002 PETER MCLAUGHLIN ZONING REVIEW Approved
09/20/2002 PMCLAUG1 FLOODPLAIN REVIEW Approved
09/20/2002 PETER MCLAUGHLIN NPPO REVIEW Passed
10/09/2002 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T02CM04306

11/05/02 10170 E. MOUNTAIN MANOR

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.


FOUNDATION PLANS:

1. PROVIDE A FOOTING UNDER THE BEARING WALL ADJACENT THE HOUSE.

2. PROVIDE SECTIONS A and B ON DRAWING A3.


FLOOR PLANS:

1. PROVIDE THE FLOOR PLAN OF THE KITCHEN AND FAMILY ROOM WITH DIMENTIONS AND WINDOW SIZES.
IS THE HOUSE EVAPORATIVE COOLED?

2. SHOW COMPLIANCE WITH R303.1 PROVIDING NATURAL LIGHT INTO EXISTING ROOMS (8%).

3. SHOW COMPLIANCE WITH R303.1 PROVIDING NATURAL VENTILATION INTO EXISTING ROOMS (4%).


STRUCTURAL PLANS:

1. HAVE AN ENGINEER JUSTIFY THE ADEQUACY OF THE TRUSSES AND THE EXISTING TRUSSES ABILITY TO CARRY THE ADDED LOAD.

2. PROVIDE THE SPAN OF THE TRUSSES BEARING ON THE "H3" HEADER.

3. SPECIFY LUMBER GRADE AND SPECIES.


ELEVATIONS:

1. SPECIFY THE ROOF SLOPE.

2. SHOW CALCULATION OF ATTIC VENTILATION AREA IN COMPLIANCE WITH R806.2. NOTE LOCATION OF ALL
VENTS NEEDED TO COMPLY.

3. NOTE GLASS IN HAZARDOUS AREAS SHALL BE SAFETY GLASS PER R308.4.




MECHANICAL PLANS:

1. PROVIDE A VENTILATION FAN IN THE BATHROOM ADJACENT THE ADDITION.

2. THE ADDITION MUST BE PROVIDED WITH HEATING CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF
68 DEGREES AT A POINT 3' ABOVE THE FLOOR PER R303.6.


ELECTRICAL PLANS:

1. PROVIDE NOTES 1, 3, and 8 FOR THE ELECTRICAL PLAN..

2. PROVIDE SMOKE DETECTORS FOR THE EXISTING SLEEPING AREAS.

3. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING ONLY APPROVED
OUTLET BOXES HAVE BEEN USED, PER E4001.6.


MODEL ENERGY CODE:

1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11.

2. CALL OUT ON THE PLANS THE "R" VALUES OF INSULATION, AS WELL AS THE "U" VALUES OF THE WINDOWS
AND DOORS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED.




IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXIMINER:
DAVE WITT @ 791-5550 EXT. 1110

Final Status

Task End Date Reviewer's Name Type of Review Description
12/02/2002 LISA LESNY OUT TO CUSTOMER Completed