Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Permit Number - T02CM04225
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/09/2002 | PETER MCLAUGHLIN | ZONING | REVIEW | Approved | |
| 09/09/2002 | PETER MCLAUGHLIN | NPPO | REVIEW | Passed | |
| 09/09/2002 | BLANCA ESPINO | FLOODPLAIN | REVIEW | Approved | |
| 09/17/2002 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T02CM04225 4748 S. 15TH AVENUE PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. FLOOR PLANS: 1. LABEL ALL ROOMS AND SPACES INCLUDING EXISTING. SHOW ALL DOORS. STRUCTURAL PLANS: 1. PROVIDE DETAIL FOR CONNECTION OF ROOF FRAMING TO EXISTING CONSTRUCTION. 2. SPECIFY OVERALL SPAN OF NEW GLULAM. 2. SILL PLATES MUST BE TREATED OR FOUNDATION GRADE REDWOOD. FLOOR LEVEL MUST BE MIN. 6" ABOVE EXTERIOR GRADE. 4. NOTE AND SPECIFY CONNECTION OF GLULAM BEAM TO EXISTING MASONRY WALL. PLUMBING PLANS: 1. PROVIDE CLEAN OUT AT KITCHEN WASTE LINE. 2. GAS: PROVIDE THE LENGTH OF LINE TO NEW RANGE LOCATION AS WELL AS TOTAL LENGTH OF GAS LINE FROM METER TO MOST REMOTE GAS APPLIANCE. 3. SHOW LOCATION OF WATER HEATER PRESSURE AND TEMPERATURE RELIEF VALVE OUTLET TO EXTERIOR. MECHANICAL PLANS: 1. GAS FURNACE AND WATER HEATER MUST DRAW COMBUSTION AIR FROM OUTSIDE. (FOR EXAMPLE, HIGH AND LOW DUCTS FROM FURNACE / WH CLOSET THROUGH ROOF.) ELECTRICAL PLANS: 1. DESIGNATE THE CIRCUIT NUMBER OF ALL REQUIRED LIGHT FIXTURES, RECEPTACLE OUTLETS, POWER OUTLETS AND SWITCHES. 2. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING ONLY APPROVED OUTLET BOXES SHALL BE USED. 3. SHOW LOCATIONS OF SMOKE DETECTORS REQUIRED PER CODE. THESE SHALL BE INSTALLED AND LOCATED AS FOR NEW CONSTRUCTION, EXCEPT THAT THEY MAY BE BATTERY OPERATED IF CEILING FINISH IS NOT BEING REMOVED IN EXISTING BEDROOMS AND HALLWAY. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: BRUCE STEVENS @ 791-5550 EXT. 110 |
| 09/21/2002 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/07/2002 | TAMI ACHONG | OUT TO CUSTOMER | Completed |