Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T02CM04111
Parcel: 12206001C

Address:
4310 E GRANT RD

Review Status: Completed

Review Details: SITE

Permit Number - T02CM04111
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/19/2002 JIM EGAN FIRE REVIEW Approved
09/24/2002 DAVID RIVERA HANDICAP-SITE REVIEW Denied insufficient ADA information provided. See ICC for ADA requirements regarding accessible ramps, slopes, parking space dimensions etc. See zoning comments.
09/24/2002 DAVID RIVERA ZONING REVIEW Denied Insufficient development information, site plan was not prepared per Development Standards 2-02. Last approved site plan was not included as requested by Patricia Gehlen.
See Development Standards 2-02 under the following website: www.ci.tucson.az.us/planning/ds/dstoc.pdf
10/01/2002 JOE LINVILLE NPPO REVIEW Denied A NATIVE PLANT PRESERVATION PLAN OR APPLICATION FOR EXCEPTION IS REQUIRED.
10/01/2002 JOE LINVILLE LANDSCAPE REVIEW Denied Copy of previously approved site/landscape plans required in addition to revised landscape plans.
OK to resubmit required by the Landscape Section. Plans will not be accepted for review without required plans.
10/15/2002 ANY FLOODPLAIN REVIEW Denied See engineering folder
10/15/2002 PAUL MACHADO ENGINEERING REVIEW Denied To: Parks and Moran, Architects
Scottsdale, Az.,85254

SUBJECT: 4310-12 E. Grant Road
Site plan T02CM04111 (First Review)
T14S, R14E, Section 03

RESUBMITTAL REQUIRED: Site Plan and Hydrology Report.

The Site Plan (SP) and Hydrology cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please provide property description per D.S. 2-02.2.1.3.
2. Please label lot dimensions and bearings per D.S. 2-02.2.1..5
3. Provide all existing and proposed buildings and structures, including location, size, height, overhangs, canopies, and use per D.S. 2-02.2.1.6.
4. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10.
5. Show all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11.
6. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12.
7. Fully-dimensioned loading space(s) and maneuvering area(s) per D.S. 2-02.2.1.14.
8. Show the limits of the 100-year floodplain and water surface elevation per D.S. 2-02.2.1.15.
9. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16.
10. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17.
11. Please show dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19.
12. All easement of record must be graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20.
13. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21.
14. Location and orientation of existing major physical features, such as railroad tracks and drainageways per D.S. 2-02.2.1.22.
15. Please provide existing topograpghic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23.
16. Show all fences, walls, or vegetation for screening and sight visibility by type, material, height, location and spacing per D.S. 2-02.2.1.27.
17. Show Development plan number on all sheets per D.S. 2-02.2.1.29.
18. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0.
19. Please provide adjacent property grades for review in accordance with in 2000 IBC section 13 concerning fills.
20. A private improvement agreement may be necessary for work performed within the Right-of-way. Contact Department of transportation at (520) 791-4249 for information.
21. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable.
22. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance with D.S 3-01.4.4.
23. List the consulting engineer and the owner/developer on the plans with the pertinent information.
24. A floodplain use permit is required.
25. Add note regarding maximizing landscaped areas 6" for water harvesting.


If you have any questions, I can be reached at 791-5550 or pmachad2@ci.tucson.az.us
Paul Machado
Senior Engineering Associate,
10/15/2002 ANY SANITATION REVIEW Denied See engineering folder.

Final Status

Task End Date Reviewer's Name Type of Review Description
02/03/2003 ANGIE SHOFFSTALL OUT TO CUSTOMER Completed