Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T02CM04054
Parcel: 128090030

Review Status: Completed

Review Details: COMMERCIAL NEW

Permit Number - T02CM04054
Review Name: COMMERCIAL NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/27/2002 PATRICIA GEHLEN ZONING REVIEW Passed
09/26/2002 RANDY SCHULER ELECTRICAL-COMMERCIAL REVIEW Approved
09/26/2002 HOLLY PEARCE PLUMBING-COMMERCIAL REVIEW Approved
09/26/2002 HOLLY PEARCE MECHANICAL-COMMERCIAL REVIEW Approved
09/26/2002 HOLLY PEARCE WATER REVIEW Approved
10/01/2002 MARTIN HAEBERLE BUILDING-COMMERCIAL REVIEW Denied 1. Provide pre-engineered building plans and calculations. Note: insure axial load transfer for seismic and winds are provided per detail 201.

2. Provide a code analysis utilizing the 2000 IBC. Include the additional structures proposed.

3. The proposed work is located on three different sites. Provide two complete sets of plans for each site.

4. Provide the minimum number of plumbing facilities for the activity buildings as per Table 2902.1 IBC.

5. As per the code analysis provided door #9 of the kitchen addition will be part of the egress system. The maximum width of the door may not exceed 48". Reference section 1003.3.1.1 IBC. Revise size of door

6. Indicate hardware proposed for door #9 within the kitchen addition.
10/07/2002 JIM EGAN FIRE REVIEW Approved
10/17/2002 GERRY KOZIOL WWM REVIEW Approved
10/17/2002 ANY FLOODPLAIN REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
10/21/2002 ELAINE ROSE OUT TO CUSTOMER Completed