| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/27/2003 | ELIZABETH EBERBACH | SANITATION | REVIEW | Approved | |
| 01/28/2003 | JIM EGAN | FIRE | REVIEW | Approved | |
| 02/12/2003 | PETER MCLAUGHLIN | HANDICAP-SITE | REVIEW | Approved | |
| 02/12/2003 | PETER MCLAUGHLIN | ZONING | REVIEW | Approved | SITE PLAN TRANSMITTAL TO: Edward Vergara 5232 E. Pima Street Tucson, AZ 85712 (520) 881-4512 FROM: Peter McLaughlin Senior Planner Development Services Dept FOR: Patricia Gehlen Principal Planner Development Services Dept. PROJECT: T02CM04034 Saguaro Christian Church School additions 8302 E. Broadway Blvd. Site Plan Review (2nd review) TRANSMITTAL: February 12, 2003 Upon completion of the following revision/addition, an over the counter review may be arranged to obtain stamped approval by the zoning review section without resubmitting the site plan. The following item must be revised on or added to the site plan: 0 1. Please revise the loading zone calc to state that one loading space is provided. Per LUC 3.4.5, the minimum length is only required to be 35 feet. DS 2-02.2.2.A.5 DS 2-02.2.1.A.14 LUC 3.4.5 2. For the educational use, please provide a count of the number of students attending the school and the square footage of office area serving the school and list the grade levels served. This information will affect the number of parking spaces required as well as the number of drop-off parking spaces required. Please revise parking calcs based on LUC 3.3.5.3 and LUC 3.3.4 (add educational use, K-8 parking required to calcs), and add a calculation of drop-off spaces required per LUC 3.5.2.7.G. Parking for the educational use (K-8) is required at one vehicle space per 10 students and one space per 250 square feet of office area. Drop-off area spaces are required at one space per 20 students, up to a total of eight spaces; with 2 lanes, and a minimum of 4 parallel stalls on the inside lane. LUC 3.3.5.3 LUC 3.3.4 LUC 3.5.2.7.G. If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 02/13/2003 | JOE LINVILLE | NPPO | REVIEW | Approved | |
| 02/13/2003 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 02/19/2003 | ELIZABETH EBERBACH | FLOODPLAIN | REVIEW | Denied | EMAIL TO ARCHITECT AFTER 19FEB03 MEETING: Hi Brian- After finishing the review, I will need a revised W.A.S.H. Report: 1) Please identify responses to all items listed in the City of Tucson Code Sec 29-15(b)(1)a through i. (Please let me know if you'd like this faxed to you.) 2) Update description of Resource Area on page 3. 3) Update the exhibit sheets with the current "W" sheets. 4) Update the reference to the Drainage Report in the Appendix (use the current report dated January 13, 2003 and all drainage addenda). 5) Submit two copies of the revised W.A.S.H. Report, attention E. Eberbach. Also, please let me know how you'd like to handle the minor boundary correction item. Elizabeth Eberbach, P.E. Civil Engineer Development Services Department City of Tucson (520) 791-5550 x 2204 |
| 02/19/2003 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Denied | EMAIL TO ARCHITECT AFTER 19FEB03 MEETING: Hi Brian- After finishing the review, I will need a revised W.A.S.H. Report: 1) Please identify responses to all items listed in the City of Tucson Code Sec 29-15(b)(1)a through i. (Please let me know if you'd like this faxed to you.) 2) Update description of Resource Area on page 3. 3) Update the exhibit sheets with the current "W" sheets. 4) Update the reference to the Drainage Report in the Appendix (use the current report dated January 13, 2003 and all drainage addenda). 5) Submit two copies of the revised W.A.S.H. Report, attention E. Eberbach. Also, please let me know how you'd like to handle the minor boundary correction item. Elizabeth Eberbach, P.E. Civil Engineer Development Services Department City of Tucson (520) 791-5550 x 2204 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/25/2003 | LISA LESNY | OUT TO CUSTOMER | Completed |