Permit Number: T02CM03869
Parcel: 134261220

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM

Permit Number - T02CM03869
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/16/2002 PETER MCLAUGHLIN ZONING REVIEW Approved
08/16/2002 PETER MCLAUGHLIN NPPO REVIEW Passed
08/16/2002 DOUG WILLIAMS FLOODPLAIN REVIEW Approved
12/17/2002 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T02CM03869

12/17/02 6910 E. NEW HAMPSHIRE

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.
2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.



FLOOR PLANS:

1. SHOW ENTIRE FLOOR PLAN OF THE BED ROOM ADJACENT THE NEW BED ROOM. SHOW ALL DOORS AND WINDOWS, ALSO PROVIDE THE SIZE OF THE ROOM.


STRUCTURAL PLANS:

1. PROVIDE JOIST HANGERS ON BOTH SIDES OF THE EXISTING FASCIA.

2. PROVIDE A DETAIL FOR THE RAFTER TO WALL CONNECTION AND SHOW THE VENTILATION IF THE RAFTERS ARE NOT "FULL THICK" WITH INSULATION.

PLUMBING PLANS:

1. WATER LINE PAGE; IF THE SOURCE IS ANY PART OF THE EXISTING WATER DISTRIBUTION SYSTEM, OTHER THAN THE METER, PROVIDE THE TOTAL DEVELOPED LENGTH AND FIXTURE DEMAND OF THE EXISTING SYSTEM.

MECHANICAL PLANS:

1. PROVIDE A VENTILATION FAN FOR THE BATH ROOM. THE WATER CLOSET COMPARTMENT IS ALSO REQUIRED TO BE VENTILATED AND IS.

ELECTRICAL PLANS:

1. THE BATH RECEPTACLE IS REQUIRED TO BE ON A 20 AMP DEDICATED CIRCUIT.

2. THE KITCHEN IS REQUIRED TO HAVE AT LEAST 2 20 AMP CIRCUITS FOR COUNTER TOP APPLIANCES.

3. THE CLOTHES WASHER IS REQUIRED TO BE ON A 20 AMP DEDICATED CIRCUIT.

4. AT LEAST ONE WALL SWITCH CONTROLLED LIGHT OR OUTLET MUST BE PROVIDED IN THE EXISTING SHOP AND OUTSIDE THE SHOP DOOR LEADING TO THE PATIO.

5. WHEN ADDITIONS OCCUR, THE RESIDENCE IS REQUIRED TO BE PROVIDED WITH SMOKE DETECTORS.




IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110
12/17/2002 MVALDEZ1 WWM REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
12/18/2002 MONICA VALDEZ OUT TO CUSTOMER Completed