Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD
Permit Number - T02CM03762
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/09/2002 | DWILLIA1 | ZONING | REVIEW | Approved | for Patricia Gehlen |
| 08/09/2002 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Approved | |
| 09/06/2002 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T02CM03762 9/6/02 435 E. 16TH ST. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FOUNDATION PLANS: 1. SPECIFY THE POST BASES ON THE PATIO. 2. PROVIDE NOTE ON THE DRAWING INDICATING THAT PRE-STRESSED OR POST-TENSIONED SLABS SHALL BE LABELED IN TWO PLACES, PER LOCAL POLICY: - CONCRETE SLAB - CENTER OF GARAGE DOOR - MAIN WATER SHUT OFF VALVE - METAL TAG INDICATING POST -TENSIONED 3. SPECIFY THE SLOPE OF THE PORCH FLOOR. FLOOR PLANS: 1. ARE THE PORCH POSTS 6X6 OR 8X8 ? ALSO, PLEASE SPECIFY A BEAM FOR THE PORCH. 2. PROVIDE THE LOCATIONS OF TEMPERED GLASS PER R308.4. IS THE FRENCH DOOR AND THE SIDE LIGHT SAFETY GLASS? STRUCTURAL PLANS: 1. PROVIDE A BEAM FOR THE PORCH END OF THE TRUSSES. 2. DOES THE CENTER BEARING APPEARS TO BE 1" OFF FOR THE TRUSSES ? 3. JUSTIFY THE LINTEL FOR THE 6-8 FOOT SPAN OR DELETE THE LINTELS FOR THE SPANS NOT USED. 4. COMPLETELY DETAIL ALL CONNECTIONS: - TRUSSES TO TOP PLATE AND BEAM - BEAM TO POST - POST TO SLAB ELEVATIONS: 1. NOTE AND SIZE ALL ROOF DRAINS OR SCUPPERS ON FLAT-ROOFED AREAS PER R903.4. 2. SHOW CALCULATION OF ATTIC VENTILATION AREA IN COMPLIANCE WITH R806.2. NOTE LOCATIONS AND SIZES OF ALL VENTS NEEDED TO COMPLY. 3. NOTE GLASS IN HAZARDOUS AREAS SHALL BE SAFETY GLASS PER R308.4. PLEASE INDICATE WHERE. SECTIONS - DETAILS - MISC. NOTES: 1. PLEASE PROVIDE A CROSS SECTION OF THE FRAME WALL. ELECTRICAL PLANS: 1. AT LEAST ONE WALL SWITCH CONTROLLED LIGHT OR OUTLET MUST BE PROVIDED AT OUTDOOR ENTRANCES TO ALL HABITABLE ROOMS PER E3801. 2. INDICATE THE LOCATION OF ALL AIR CONDITIONING AND HEATING UNITS, AIR HANDLERS, COMPRESSORS AND DISCONNECTS AND PROVIDE ELECTRICITY. 3. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING ONLY APPROVED OUTLET BOXES SHALL BE USED, PER E4001.6. MODEL ENERGY CODE: 1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11. 2. CALL OUT ON THE PLANS THE "R" VALUES OF INSULATION, AS WELL AS THE "U" VALUES OF THE WINDOWS AND DOORS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 |
| 09/10/2002 | PATRICIA GILBERT | NPPO | REVIEW | Passed | S99-010 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/13/2002 | TAMI ACHONG | OUT TO CUSTOMER | Completed |