Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T02CM03483
Parcel: 122060100

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM

Permit Number - T02CM03483
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/23/2002 DAN CASTRO ZONING REVIEW Approved
07/23/2002 DAN CASTRO NPPO REVIEW Passed
08/26/2002 DOUG WILLIAMS FLOODPLAIN REVIEW Approved
08/27/2002 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T02CM03483

2113 N. CATALINA AVE. 8/30/02

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

SITE PLAN:

1. PROVIDE 6' MINIMUM DISTANCE BETWEEN THE
NEW SLEEPING QUARTERS AND THE PRIMARY RESIDENCE OR A ONE HOUR FIRE WALL IS REQUIRED. HOWEVER IF THE ROOFS ARE CONNECTED, THE FIRE WALL IS NOT REQUIRED IF THEY ARE LESS THAN 6' APART.

2. INDICATE THE LOCATION OF GAS, WATER, ELECTRIC AND SEWER OR SEPTIC LINE ON THE PROPERTY, AND
WHERE THEY ENTER THE BUILDING. PROVIDE THE LOCATION OF YOUR WATER METER AND SEPTIC SYSTEM
IF IT EXISTS.

FOUNDATION PLANS:

1. DIMENSION THE FOOTING WIDTH AND DEPTH INTO UNDISTURBED SOIL.


2. NOTE AND DETAIL MINIMUM REINFORCING, OR PROVIDE CODE JUSTIFICATION OF ALTERNATE:

MONOLITHIC - ONE (1) #5 OR TWO (2) #4 REBARS IN THE MIDDLE OF THE FOOTING.

3. FOOTING WIDTHS FOR ONE-STORY, PER TABLE R403.1:

16" MINIMUM; WOOD FRAME

4. SHOW THE LANDING AT THE DOOR SPECIFIED.

FLOOR PLANS:

1. SHOW THAT THE WATER CLOSET IS LOCATED IN A CLEAR SPACE NOT LESS THAN 30" WIDE AND HAS A
CLEAR SPACE IN FRONT OF NOT LESS THAN 24" PER R307.2 (FIGURE).

STRUCTURAL PLANS:

1. PROVIDE A LISTING FOR THE "A-2" AT THE RAFTER/PLATE CONNECTION SHOWN IN DETAILS 1 & 2 ON S-1.

2. PLEASE RELOCATE THE NOTE REGARDING THE H-2.5 AT THE RAFTER TO DOUBLE TOP PLATE.

3. PLEASE CONFIRM THE STUD SIZE.

SECTIONS - DETAILS - MISC. NOTES:

1. SPECIFY THE LENGTH OF ANCHOR BOLTS FOR SILL PLATES.

PLUMBING PLANS:

1. PROVIDE ¾" SUPPLIES.

2. PLEASE DRAW THE ISOMETRIC AS IT WILL BE INSTALLED.

3. PLEASE DARKEN THE PLUMBING.

4. NOTE ON THE PLANS THAT THE EXISTING SEWER UNDER THE BUILDING AND TWO FEET BEYOND IS TO BE OF A MATERIAL APPROVED FOR UNDER FLOOR USE.

5. NOTE ON THE PLAN COMPLIANCE WITH WATER CONSERVATION ; WATER CLOSETS 1.6 GALLONS PER FLUSH, SINKS AND SHOWER HEADS 3 GALLONS PER MINUTE.

6. NOTE ON PLANS THAT SHOWERS THAT HAVE INDIVIDUAL CONTROL
VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE.

ELECTRICAL PLANS:

1. PLEASE DARKEN THE ELECTRIC SYMBOLS AND CLARIFY THEM ON THE ON THE ELECTRIC SYMBOL LEGEND.

2. SUB-PANELS ARE NOT PERMITTED IN CLOSETS. PLEASE RELOCATE.

3. A RECEPTACLE OUTLET SHALL BE PROVIDED ADJACENT TO THE BASIN IN EACH BATHROOM, PER E3801.6.
BATHROOM OUTLETS SHALL BE ON A SEPARATE 20 AMP CIRCUIT WITH NO OTHER OUTLETS, PER E33603.4.

4. SHOW THE LOCATION OF THE SMOKE DETECTOR PER R317. THE SLEEPING AREAS IN THE EXISTING RESIDENCE ARE REQUIRED TO BE EQUIPPED WITH SMOKE DETECTORS (BATTERY OKAY) IF THE ROOFS ARE CONNECTED.


MODEL ENERGY CODE:

1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11.

2. CALL OUT ON THE PLANS THE "R" VALUES OF INSULATION, AS WELL AS THE "U" VALUES OF THE WINDOWS
AND DOORS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED.


IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110
09/04/2002 GERRY KOZIOL WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
09/05/2002 TAMI ACHONG OUT TO CUSTOMER Completed