Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T02CM03458
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/31/2003 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T02CM03458 1/31/03 1048 E. HEDRICK DR. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. SITE PLAN: 1. INDICATE THE LOCATION OF THE WALL THAT IS REQUIRED TO BE A ONE HOUR FIRE WALL DUE TO PROXIMITY TO PROPERTY LINE. FOUNDATION PLANS: 1. THE 2X12s@24"OC APPEAR TO BE OVERSPANNED OVER THELAUNDRY AREA. DO YOU WANT TO ADD A FOOTING……OR ? 2. ONE OF THE POSTS ON THE BACK PORCH, ACROSS FROM THE LAUNDRY, IS MISSING A FOOTING. 3. POST FOOTING SIZES ON THE PORCH CONFLICT WITH DTL. 11/A2. 4. PLEASE SPECIFY THE LENGTH OF THE ANCHOR BOLTS. FLOOR PLANS: 1. PROVIDE A FIRE WALL , AND DETAIL, WHERE LESS THAN 3 FEET FROM THE PROPERTY LINE. 2. PROVIDE ALL WINDOW SIZES AND TYPES, AND DESIGNATE THE OPERABLE PORTION OF WINDOWS, AS WELL AS THE LOCATIONS OF TEMPERED GLASS PER R308.4. 3. SHOW COMPLIANCE WITH R310 PROVIDING EGRESS FROM BEDROOMS. - MAXIMUM SILL HEIGHT OF 44" - MINIMUM NET CLEAR AREA OF OPENING OF 5.7SF. - MINIMUM NET CLEAR DIMENSIONS OF OPENING OF 24" HEIGHT BY 20" WIDTH. 4. NOTE THAT BATHTUB ENCLOSURES SHALL BE FINISHED PER p2710 WITH CERAMIC TILE, OR A LISTED ENCLOSURE, TO A HEIGHT OF 72" ABOVE THE DRAIN PER R702.4 AND R307.2 STRUCTURAL PLANS: 1. THE 2X12@24"OC APPEAR TO BE OVER SPANNED OVER THE LAUNDRY AREA. 2. THE 2X6@24"OC APPEAR TO BE OVER SPANNED OVER THE BACK PORCH NEAR THE FURNACE. 3. THE 6X8 PORCH BEAM APPEARS TO BE OVER SPANNED NORTH OF THE EXISTING BATH ROOM. 4. JUSTIFY THE 3'3" CANTILEVER OF THE 6X8 FRONT PORCH BEAM NEAR THE EXISTING BEDROOM. 5. THE BEAM IN DETAIL 4/A2 DIFERS FROM THE PLAN. 6. HOW ARE THE PORCH RAFTERS CONNECTED TO THE EXISTING HOUSE ? 7. THE RAFTERS IN DETAIL 1/A3 CONFLICT WITH THE PLAN. 8. DTL. 3/A3 , PROVIDE A TRIM/LEDGER CONNECTION OR MOVE THE H2.5 TO THE LEDGER. PLUMBING PLANS: 1. GAS: PROVIDE THE LENGTH OF LINE TO EACH APPLIANCE, BTU DEMAND OF EACH APPLIANCE, SIZE OF EACH BRANCH, TOTAL DEMAND & TOTAL DEVELOPED LENGTH FROM METER TO MOST REMOTE APPLIANCE ON THE SYSTEM PER UPC 1217.2 MECHANICAL PLANS: 1. PLEASE PROVIDE RETURN AIR FOR THE MECHACICAL SYSTEMS, SIZED IN ACCORD WITH M1602.2 . 2. GAS APPLIANCES SHALL COMPLY WITH CHAPTER 17 COMBUSTION AIR REQUIREMENTS. PLEASE DETAIL HOW. ELECTRICAL PLANS: 1. RECEPTACALS ARE MISSING ON THE NORTH WALL OF THE DINING ROOM. 2. PROVIDE AN EXTERIOR OUTLET AT GRADE LEVEL LOCATED AT THE FRONT OF THE DWELLING, PER E3801.7. THIS OUTLET SHALL BE GFI PROTECTED PER E3802.3. 3. RECEPTACLE OUTLETS SHALL BE PROVIDED AT EACH KITCHEN COUNTER SPACE WIDER THAN 12", AND SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24" FROM A RECEPTACLE OUTLET, PER E3801.4.1 4. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING ONLY APPROVED OUTLET BOXES SHALL BE USED, PER E4001.6. 5. NOTE THAT LIGHT FIXTURES IN CLOTHES CLOSETS SHALL BE INSTALLED IN ACCORDANCE WITH E3903.11. 6. PROVIDE SMOKE DETECTORS FOR THE NEW MASTER BEDROOM. SEE, ALSO, R317.1.1 AND PLEASE NOTE ON THE PLANS. MODEL ENERGY CODE: 1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11. 2. CALL OUT ON THE PLANS THE "R" VALUES OF INSULATION, AS WELL AS THE "U" VALUES OF THE WINDOWS AND DOORS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/05/2003 | ELAINE ROSE | OUT TO CUSTOMER | Completed |