Permit Review Detail
Review Status: Active
Review Details: SITE
Permit Number - T02CM03367
Review Name: SITE
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/20/2002 | JIM EGAN | FIRE | REVIEW | Approv-Cond | |
| 09/11/2002 | DAN CASTRO | HANDICAP-SITE | REVIEW | Passed | |
| 09/11/2002 | DAN CASTRO | ZONING | REVIEW | Approved | |
| 09/12/2002 | DAN CASTRO | NPPO | REVIEW | Approved | |
| 09/12/2002 | DAN CASTRO | LANDSCAPE | REVIEW | Approved | |
| 09/24/2002 | MATT FLICK | SANITATION | REVIEW | Passed | |
| 10/07/2002 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Approv-Cond | conditions pending... |
| 10/07/2002 | ELIZABETH EBERBACH | FLOODPLAIN | REVIEW | Approved | |
| 10/07/2002 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Approv-Cond | SUBJECT: Aircraft Rescue and Fire Fighting Training Facility Engineering & Floodplain Review REVIEWER: Elizabeth Eberbach DATE: October 7, 2002 ACTIVITY NUMBER: T02CM03367 SUMMARY: Engineering has received and reviewed the Civil Drawings and Specifications Report for Site Plan Review, and recommends conditional approval with the four conditions stated below. SITE PLAN CONDITIONS OF APPROVAL 1) City of Tucson Development Standards (DS) Section No.2-03.2.4.L.5: Approval documentation and permits from other jurisdictions for acceptance of proposed construction shall be obtained. 2) Offsite disposal location for overexcavated soils and other deleterious materials shall be placed in an approved and permitted site. 3) Proposed project exceeds 5 acres and is subject to NPDES requirements. Contact Loren Makus, 791-4251 for submittal requirements. 4) IBC Chapter 36, Section 9: A Grading Plan submittal is required to obtain the grading permit. For the Grading Permit, submit the civil drawings that have the above site plan conditions, as well as the following grading comments, addressed: a) DS Sec.2-02.2.1.A.5: On sheet C1.0, label property lines. b) DS Sec.2-02.2.1.A.17: Section 02200 is missing from the Specifications Report; provide earthwork quantities. c) DS Sec.2-02.2.1.A.35: Provide method of restricting public access. d) DS Sec.2-05.3.2.A: Update Specifications Report Section 02220 Part 3.5; provide soil testing results and description of soil suitability for this project. e) DS Sec.3-01.3.1.A: Will pavement design section on Arff Road and First Street be sufficient for fuel tanks and craft delivery vehicles? f) DS Sec.3-01.3.2.C: On sheet C3.1 and C5.1: Will curb radii be sufficient turning movement area for fuel tanks and craft delivery vehicles at First Street and Arff Road? g) DS Sec.3-01.10.Fig.8: On sheet C3.3, provide minimum 0.5% longitudinal grade. Also, provide minimum 100 feet for vertical curves for road profiles. For any questions or to expedite the grading permit, call me at 791-5550, extension 2204. Elizabeth Eberbach, PE Civil Engineer Engineering Section Development Services |