Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T02CM03236
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/09/2002 | JIM EGAN | FIRE | REVIEW | Approved | |
| 07/09/2002 | ANY | FLOODPLAIN | REVIEW | Approved | |
| 07/09/2002 | ANY | ENGINEERING | REVIEW | Approved | |
| 07/09/2002 | ANY | SANITATION | REVIEW | Approved | |
| 07/11/2002 | PATRICIA GEHLEN | HANDICAP-SITE | REVIEW | Approved | |
| 07/22/2002 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | TO: Metro Permit Express 1010 N. Alvernon Way Tucson, AZ 85711 (520) 977-7187 From: Peter McLaughlin, Senior Planner Development Services Dept. FOR: PATRICIA GEHLEN Principal Planner Development Services Dept. PROJECT: T02CM03236 New Medical Office Addtion 2255 N. Wyatt Drive Tucson, AZ 85711 Site Plan Review (1st review) TRANSMITTAL: July 22, 2002 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This project is being reviewed as less than a 25% expansion. DS 2-02 2. The submitted site plan does not show the same configuration of the back-up spur at the north end of the parcel 2 as is shown on the approved site plan. Dimension the depth and width of the back-up spur. Does it have a 5-foot radius to allow vehicles to back up as is shown on the approved plan? Also, the wheelstops, as shown on the approved plan, must be shown and dimensioned two-and-one-half (2½) feet from front of parking spaces. DS 3-05.2.3.C.2 3. Revise the use under Zoning Data to read "Medical service-outpatient". Add the development designator "35" to the data. Medical service uses in the OCR-1 zone is subject to LUC 3.5.4.8.B. Please add a note detailing this restriction. LUC 2.6.1.2.A.10 4. Correct the zoning to read "OCR-2". Add the adjacent zoning (also OCR-2) to the site plan. DS 2-02.2.1.A.2 5. Provide a Floor Area Ratio calculation and remove the lot coverage information. The maximum allowed FAR is 6.00. The proposed FAR is calculated as gross floor area divided by site area. DS 2-02.2.2.A.2 6. The math in the vehicle parking calc is incorrect. Vehicle parking for the medical service use is calculated at one (1) vehicle space per 175 square feet of floor area. If the gross floor area is 9098 as shown, the number of vehicle spaces required is 52. DS 2-02.2.2.A.4 LUC 3.3.4 7. Show the location of the existing bicycle parking spaces on the site plan. DS 2-02.2.1.A.9 8. The existing loading are is being removed as part of this project. A loading zone is required for the site. Show the location of the loading zone, fully dimensioned, on the site plan. DS 2-02.2.1.A.14 LUC 3.4.5.4 9. Provide the dimensions and height of the proposed addition on the site plan. DS 2-02.2.2.A.6 10. Because the configuration of the building is slightly different from that shown on the approved site plan, dimension the building setback to the south property line along Farness Street. DS 2-02.2.1.A.7 11. Because the project is more than a tenant improvement, revise the title block to also state that there is an addition proposed. 12. Label the existing drainageway, which runs between the two parcels. 13. If any new free-standing outdoor lighting or signage is proposed for this site, please detail on the site plan. DS 2-02.2.1.A.13 & 25 If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 07/29/2002 | JOE LINVILLE | NPPO | REVIEW | Passed | Previously approved site. |
| 07/29/2002 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/30/2002 | LISA LESNY | OUT TO CUSTOMER | Completed |