Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T02CM03231
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/06/2003 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T02CM03231 2/06/03 781 N. ANITA AVE. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FOUNDATION PLANS: 1. DTL. 5.1 ONA.7 , DEPTH OF FOOTING IS LESS THAN 12". SEE R403.1.4 . 2. DTLS. 2.1 & 3.1 ON A.7 , SPECIFY THE LENGTH OF THE ANCHOR BOLTS. 3. THE WIDTH OF "F-02" IS LESS THAN 16". SEE R403. 4. PROVIDE HOLD-DOWNS FOR THE BRACED WALL PANELS IN THE WALL COMMON TO THE PORCH AND THE BEDROOMS. SEE R602.10 . FLOOR PLANS: 1. NOTE THAT BATHTUB ENCLOSURES SHALL BE FINISHED PER p2710 WITH CERAMIC TILE, OR A LISTED ENCLOSURE, TO A HEIGHT OF 72" ABOVE THE FLOOR PER R702.4 AND R307.2 STRUCTURAL PLANS: 1. DIMENSION THE LOCATION OF THE BEAM FOR THE AWNING AS WELL AS THE WIDTH OF THE AWNING. 2. PROVIDE A RAFTER TO WALL CONNECTION FOR "STOR 210" . 3. SPECIFY LUMBER GRADE AND SPECIES FOR THE RAFTERS. ELEVATIONS: 1. PLEASE PROVIDE THE DIAMETER OF THE CANALES. SECTIONS - DETAILS - MISC. NOTES: 1. SHOULD THE SECTION LINE ON A4'S ROOF PLAN REFER TO 2 ON A6 ? 2. DTL. 12.2 ON A.8 , PLEASE SPECIFY THE LENGTH AND DIAMETER OF THE LAGS INTO THE BLOCKS AND THE BLOCK TO STUD CONNECTION. PLUMBING PLANS: 1. NOTE AND SPECIFY ALL PIPING MATERIALS. 2. THE FIXTURE UNITS SHOULD BE IN ACCORD WITH THE STATE PLUMBING CODE ( AMMENDED '94 U.P.C.). 3. PROVIDE APPENDIX A , U.P.C. , JUSTIFICATION OF THE WATER SERVICE BRANCHES BEFORE THE WATER HEATER. 4. WATER LINE: PROVIDE TOTAL FIXTURE DEMAND & MAXIMUM DEVELOPED LENGTH 5. NOTE ON PLAN COMPLIANCE WITH WATER CONSERVATION; WATER CLOSETS 1.6 GALLONS PER FLUSH, SINKS AND SHOWERHEADS 3 GALLONS PER MINUTE. 6. NOTE ON PLANS THAT SHOWER AND TUB / SHOWER COMBINATIONS THAT HAVE INDIVIDUAL CONTROL VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE. 7. ANY HOSE BIBS ? MECHANICAL PLANS: 1. NOTE ON PLANS: MECHANICAL SHALL COMPLY WITH CHAPTERS 12 - 24 2000 IRC. 2. PROVIDE 100 SQ. INCHES OF COMBUSTION AND RELIEF AIR TO THE FURNACE AND WATER HEATER . SEE THE STATE PLUMBING CODE. ELECTRICAL PLANS: 1. NOTE ON PLANS: ELECTRICAL WORK SHALL COMPLY WITH CHAPTERS 33 - 42, 2000 IRC. 2. PLEASE CHECK T.E.P. SERVICE ENTRANCE REQUIREMENTS FOR THE SIZE OF THEIR CONDUIT ON THE LINE SIDE OF THE METER. 3. DO THEY MAKE A 25 AMP CIRCUIT BREAKER FOR CKT. 12/14 ? IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 NOTE: AS OF 2-02-01 THE CITY OF TUCSON HAS ADOPTED THE 2000 IRC EXCEPT FOR THE PLUMBING PORTION WHICH IS THE STATE PLUMBING CODE. ALL MODEL PLANS SHALL BE REFERENCE TO THE PREVIOUSLY MENTIONED CODES. |
| 02/11/2003 | GERRY KOZIOL | WWM | REVIEW | Denied | Needs to review location of connection to public sewer and joint use agreements. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/13/2003 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |