Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING
Permit Number - T02CM03216
Review Name: RESIDENTIAL BLDG/ZONING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/08/2002 | DAN CASTRO | ZONING | REVIEW | Approved | |
| 07/08/2002 | DAN CASTRO | NPPO | REVIEW | Passed | |
| 07/31/2002 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #TO2CM03216 7/31/02 560 S. SAMANIEGO AVE. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. SITE PLAN: (NOT REQUIRED FOR MODEL PLANS) 1. INDICATE THE LOCATION OF GAS AND SEWER OR SEPTIC SYSTEM ON THE PROPERTY. FOUNDATION PLANS: 1. CONCRETE NOTE #5 CONFLICTS WITH R403.1.4's REFERENCE TO ONLY UNDISTURBED EARTH. 2. DIMENSION THE FOOTING WIDTH THICKNESS PER TABLE R403.1 . 3. NOTE AND DETAIL MINIMUM REINFORCING, OR PROVIDE CODE JUSTIFICATION OF ALTERNATE: - STEMWALL - ONE (1) #4 REBAR IN THE BOTTOM OF THE FOOTING AND ONE (1) #4 REBAR IN THE TOP OF THE STEM ON BRACED WALLS PER R602.10.6 4. ALL FOUNDATION HOLD-DOWNS AND ANCHOR BOLT SPACING FOR BRACED WALL PANELS SHALL BE SPECIFIED AND LOCATED i.e. NORTH OF THE GARAGE DOOR. FLOOR PLANS: 1. SHOW COMPLIANCE WITH R303.1 PROVIDING NATURAL LIGHT INTO EXISTING BEDROOM (8%) . 2. SHOW COMPLIANCE WITH R303.1 PROVIDING NATURAL VENTILATION INTO EXISTING BEDROOM (4%). 3. COMPLY WITH R309.2. PROVIDE ½" GYPSUM BOARD ON ALL WALLS COMMON TO THE GARAGE AND HOUSE. IS THE WINDOW TO BE CLOSED UP ? 4. IDENTIFY THE BRACED WALL PANEL NORTH OF THE GARAGE DOOR . STRUCTURAL PLANS: 1. CARPENTRY NOTE #1 SHOULD REFER TO THE 2000 I.R.C. 2. SPECIFY THE JOIST HANGERS . 3. DETAIL THE BRACED WALL CONNECTION AT THE FOUNDATION. SECTIONS - DETAILS - MISC. NOTES: 1. THE NAILING OF THE H2.5 IN DETAIL 5/A-2 CONFLICTS WITH IT'S LISTING. 2. THE CURRENT SIMPSON CATALOG SHOWS NO LISTING FOR AN A-24. SHOULDN'T THIS BE A MOMENT CONNECTION IN DETAIL 11/A-2 ? 3. JUSTIFY 3-16d PER STUD IN DETAIL 5/A-2 FOR THE LEDGER TO WALL CONNECTION. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 110 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/02/2002 | TAMI ACHONG | OUT TO CUSTOMER | Completed |