Permit Number: T02CM03181
Parcel: 134030300

Address:
8935 E 21ST ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/FLOOD

Permit Number - T02CM03181
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/03/2002 DAVID RIVERA ZONING REVIEW Approved
07/03/2002 JAMES TATE FLOODPLAIN REVIEW Approved
07/03/2002 DAVID RIVERA NPPO REVIEW Passed
10/02/2002 PIMA COUNTY BUILDING-RESIDENTIAL REVIEW Denied PIMA COUNTY DEVELOPMENT SERVICES
201 N. Stone Av. 1st. Floor
Tucson Arizona 85701
Department of Building and Safety
Correction Sheet 1 of 1


ADDRESS : 8935 E 21st ST T02CM03181
WORK : WORKSHOP DATE : 10/02/02
OCCUPANCY : U CONST. V-B
ENGINEER : STEVEN W HILL PHONE : 520-
APPLICANT : DAVID WHITE PHONE : 520-290-2646


GENERAL COMMENTS

Foundation design, development, embedment and hook length of anchor bolts in the concrete are design responsibility of the engineer of record. Also, shear angles, tension plates, hairpins and any other embedded material in the concrete shall be designed by the engineer of record. Provide complete structural calculations for design of the foundation system.

Provide complete specifications on the plans for all structural materials used in the foundation system.

1704.3.3 High-Strength Bolts. Special inspection is required for the installation of high strength bolts.

1704.3.2. Steel Frame Construction -- Details. Special inspection is required for steel frame to verify compliance with the details shown on the approved construction documents, such as bracing, stiffening elements, member locations and proper application of joint details at each connection.

A SPECIAL INSPECTION CERTIFICATE, furnished by the City of Tucson is required to be completed and signed by the Owner and Engineer responsible for carrying out the required special inspections prior to obtaining a building permit. Please note that the Owner or his Legal Agent must also sign the Special Inspection Certificate.

I am available between 8:00 A.M. to 12:00 noon and 2:00 P.M. to 4:00 P.M. daily. Please feel free to call or make an appointment to discuss or clarify any of these comments.


EDWARD J. COURTNEY
520-740-6492

Final Status

Task End Date Reviewer's Name Type of Review Description
12/27/2002 TAMI ACHONG OUT TO CUSTOMER Completed