Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Permit Number - T02CM03152
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/07/2003 | DAN CASTRO | ZONING | REVIEW | Approved | |
| 01/07/2003 | DAN CASTRO | NPPO | REVIEW | Passed | |
| 01/07/2003 | TERRY STEVENS | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T02CM03152 1/22/03 PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. GENERAL REQUIREMENTS: 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. SITE PLAN: 1. ONLY ONE ELECTRIC SERVICE DROP IS ALLOWED FOR EACH STRUCTURE. PLAN INDICATES TWO. 2. PLAN INDICATES STRUCTURE IS 3'-4" FROM PROPERTY LINE. FRAMING PLAN INDICATES A 2' ROOF OVER HANG. THE MAX. PROJECTION CAN NOT EXCEED 1/3 THE REQUIRED SET BACK WHERE A FIREWALL IS REQUIRED. IN THIS CASE THE MAX. EAVE ALLOWED IS 1'-4", ALSO THE UNDER SIDE OF THE EAVE WITH IN 3' OF THE PROPERTY LINE REQUIRES 5/8" TYPE "X" GWB OR 3 COAT STUCCO. INDICATE HOW THIS IS DONE ON THE FRAMING PLAN. FOUNDATION PLANS: 1. INDICATE THE SLOPE FOR EXTERIOR SLABS, PER R312. FLOOR PLANS: 1. A ONE HOUR WALL IS REQUIRED BETWEEN UNITS. CLEARLY INDICATE HOW UNITS WILL BE COMBINED. 2. NOTE THAT BATHTUB AND SHOWER ENCLOSURES SHALL BE FINISHED WITH CERAMIC TILE, OR A LISTED ENCLOSURE, TO A HEIGHT OF 72" ABOVE THE DRAIN PER R702.4 AND R307.2 STRUCTURAL PLANS: 1. PROVIDE DETAIL OF ONE HOUR RATED WALL BETWEEN UNITS. MUST EXTEND TO BOTTOM OF ROOF DECK FRAMING PLANS INDICATE EAVE ON BOTH ENDS 2. PROVIDE DETAIL OF FIRE RATING OF EAVES AND INDICATE MAX. 1'-4" OVER HANG ALONG WALL NEAR PROPERTY LINE. 3. BY FIRE RATING EAVES AS REQUIRED WILL CHANGE THE VENTING FOR ATTIC SPACE BY BLOCKING THE BIRD BOARDS 4. MASONRY LINTELS INDICATED ARE INADEQUATE FOR SPANS GREATER THAN 3'. 2-31/2 X 31/2 X 1/4 FOR OPENINGS 3' TO 4' 2-4 X 3/12 X 5/16 FOR OPENINGS 4' TO 7' 5. DETAIL 1/S-1 ANCHOR BOLT SIZE AND SPACING MISSING ELEVATIONS: 1. SHOW CALCULATION OF ATTIC VENTILATION AREA IN COMPLIANCE WITH R806.2. NOTE LOCATION OF ALL VENTS NEEDED TO COMPLY. PLUMBING PLANS: 1. WATER LINE: PROVIDE TOTAL FIXTURE DEMAND & MAXIMUM DEVELOPED LENGTH FOR BOTH UNITS IF USING ONLY ONE METER. 2. NOTE ON PLAN COMPLIANCE WITH WATER CONSERVATION; WATER CLOSETS 1.6 GALLONS PER FLUSH, SINKS AND SHOWERHEADS 3 GALLONS PER MINUTE. 3. PROVIDE PRESSURE AND TEMPERATURE RELIEF VALVE AT WATER HEATER. 4. THE CITY OF TUCSON HAS NOT ADOPTED THE PLUMBING SECTION OF THE IRC 2OOO. THE CURRENT CODE BEING USED IS THE 1994 UPC WITH THE STATE AMENDMENTS. ALL PLANS MUST REFERENCE TO THIS CODE. 5. 2" MAIN WASTE LINE? SHOULD BE 3". ALSO 2 WAY CLEANOUT MISSING 6. INDICATE VENT SIZE AT KITCHEN SINK ON PLAN VIEW MECHANICAL PLANS: 1. NOTE ON PLANS: MECHANICAL SHALL COMPLY WITH CHAPTERS 12 -16 AND18- 24 2000 IRC. 2. GAS APPLIANCES SHALL COMPLY WITH 1994 UPC WITH STATE AMENDMENTS FOR COMBUSTION AIR REQUIREMENTS. DETAIL HOW. ELECTRICAL PLANS: 1. NOTE ON PLANS: ELECTRICAL WORK SHALL COMPLY WITH CHAPTERS 33 - 42, 2000 IRC. 2. NOTE THE LOCATION, TYPE AND AMPERAGE OF THE PANEL. NOTE THE GROUNDING AND BONDING METHOD. INDICATE A DUAL PACK----ONLY ONE SERVICE DROP PER STRUCTURE 3. #8 WIRE INADEQUATE FOR 60 AMP BREAKER 4. CLARIFY THE LOCATION AND ACCESS TO THE SUB-PANEL.------------IF APPLIES. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: TERRY STEVENS @ 791-5550 EXT. 1112 |
| 01/07/2003 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Approved | |
| 01/24/2003 | GERRY KOZIOL | WWM | REVIEW | Denied | Needs to show location of connection to sewer. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/29/2003 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |