Permit Number: T02CM03109
Parcel: 107110820

Address:
3154 N STONE AV

Review Status: Completed

Review Details: SITE

Permit Number - T02CM03109
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/09/2002 JIM TATE ENGINEERING REVIEW Denied The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all engineering, flood plain, and solid waste comments have been addressed.

1. The sidewalk location for an MS&R street with a right-of-way width of 100 ft. is 2.5 ft. from face of future curb. The plan shows 1.5 ft.

2. The sight visibility stem side dimension should be 20 ft. The near side is 345 ft. and the far side is 125 ft. See DS 3-01.5.3 and DS 3-01 Figure 16

3. Enclosures for dumpster containers require steel pipes between the container and the enclosure's rear and sidewalls. The purpose of the pipes is to prevent the container from damaging the enclosure while being serviced. The pipes provided on the plan do not protect the enclosure while it is being serviced. DS 6-01.4.2.C.2
08/09/2002 JIM TATE SANITATION REVIEW Denied See Engineering Folder.
08/09/2002 JAMES TATE FLOODPLAIN REVIEW Approved Flood Use Permit No. T02OT00971
08/15/2002 DAVID RIVERA ZONING REVIEW Approved
08/28/2002 JOE LINVILLE LANDSCAPE REVIEW Denied Revise the plan to eliminate plants that grow in excess of thirty inches high and plants that are not listed on the ADWR Plant List from the right of way areas.

Final Status

Task End Date Reviewer's Name Type of Review Description
08/30/2002 TAMI ACHONG OUT TO CUSTOMER Completed