Permit Number: T02CM03066
Parcel: 13217141A

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T02CM03066
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/25/2002 ANY FLOODPLAIN REVIEW Approved
06/26/2002 JIM EGAN FIRE REVIEW Approved
06/27/2002 HOLLY PEARCE PLUMBING-COMMERCIAL REVIEW Denied Plumbing 1.Provide a civil site plan with FFE, M H Rim elev., sewer and water lines. 2. Provide the manufactures name and listings for all plumbing fixtures on the plan. 3. Venting does not comply with Sec 904.1 UPC 1994 Az. Code. 4. Provide clean outs on the service sink and urinals. 5. Provide a water demand calculation based on Appendix 'A' UPC 1994 Az. Code. on the plan.
06/27/2002 HOLLY PEARCE MECHANICAL-COMMERCIAL REVIEW Denied Mechanical 1. Provide established data showing that metal has an R-value of .33 and 1.50, also 8" CMU with a R-2. 2. Show on the plan how the mechanical design complies with Chapter 4 IMC 2000. 3. Provide access to the equipment on the roof, show on the plan. 4. Provide condensate lines on the units, show on the plan , size and discharge location.
07/01/2002 PHIL SEADER BUILDING-COMMERCIAL REVIEW Approved
07/03/2002 RANDY SCHULER ELECTRICAL-COMMERCIAL REVIEW Approved
07/05/2002 FRANK KALINSKI WATER REVIEW Approved
07/08/2002 GERRY KOZIOL WWM REVIEW Approved
07/08/2002 PATRICIA GEHLEN ZONING REVIEW Denied 7/8/02 - Zoning- A revised site plan and site card are required for approval. The site plan must be revised to include parking calculations for all uses on site (not just the church). Also, the locations of the proposed bicycle parking must be shown on the revised site plan fully dimensioned. All calculations must be based on all uses on the site. For example the loading zones and bicycle parking calculations must be revised to be based on all uses on the site not just the church.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/09/2002 DELMA ROBEY OUT TO CUSTOMER Completed