Permit Number: T02CM03047
Parcel: 116122830

Review Status: Completed

Review Details: COMMERCIAL NEW

Permit Number - T02CM03047
Review Name: COMMERCIAL NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/26/2002 DAN CASTRO ZONING REVIEW Approved
07/03/2002 JIM EGAN FIRE REVIEW Approved
07/09/2002 HOLLY PEARCE PLUMBING-COMMERCIAL REVIEW Denied Plumbing 1. Provide a civil site plan with FFE and sewer lines that attach to a sewer main. 2. Roof and overflow drains can not attach to each other. NOTE: Detail 12/A9.1 incorrect. A screen is required on the overflow also. 3. Provide a complete waste line isometric drawing. NOTE: drawing on TP1.0 is unacceptable as a isometric drawing. NOTE: Waste lines attaching to the main trunk going in opposite directions.
07/09/2002 HOLLY PEARCE MECHANICAL-COMMERCIAL REVIEW Denied Mechanical 1. Incorrect MEC calculations submitted. ASHRAE/IES 90.1-1989 Version 2.4 required. 2. Show on the plan how the mechanical design complies with Chapter 4 IMC 2000. 3. Provide condensate lines, size and discharge location on the plan.
07/16/2002 TOM CLARK WATER REVIEW Approv-Cond
07/25/2002 RANDY SCHULER ELECTRICAL-COMMERCIAL REVIEW Denied
07/29/2002 PIMA COUNTY BUILDING-COMMERCIAL REVIEW Denied See attached comments.
08/05/2002 GERRY KOZIOL WWM REVIEW Denied See attached comments.
08/05/2002 PAUL MACHADO FLOODPLAIN REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
08/08/2002 LISA LESNY OUT TO CUSTOMER Completed