Permit Number: T02CM03020
Parcel: 117141030

Address:
340 S STONE AV

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T02CM03020
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/12/2002 PAUL MACHADO FLOODPLAIN REVIEW Approved
11/13/2002 JIM EGAN FIRE REVIEW Approved
11/14/2002 DAVID RIVERA ZONING REVIEW Approved
11/26/2002 MARTIN HAEBERLE BUILDING-COMMERCIAL REVIEW Approved
12/03/2002 LINDA BUCZYNSKI ELECTRICAL-COMMERCIAL REVIEW Denied Please return the plans I have already reviewed along with your next submission.

1) Fixture cut for fixture F does not indicate lumen output. Please note F fixture must have a minimum efficiency of 45 lumens/watt, and that incandescent sources do not meet this criterion. Also note that the 200W indicated on the cut sheet does not match the 100W on the Lighting Fixture Schedule.


2) IECC light budget calculations submitted for the interior still do not meet the requirements according to our calculations. Submitted calculations use a Compact Fluorescent Fixture with (2) 32 W bulbs, whereas our calculation properly uses (2) 42 W bulbs per the Lighting Fixture Schedule. Submitted calculations use an Incandescent Wall Fixture with (1) 60 W bulb, whereas our calculation properly uses (2) 60 W bulbs per the Lighting Fixture Schedule.
3)
USE PERMITTED W/FT2 AREA FT2 WATT/FT2 TOTAL ACTUAL
Banking 2 1689 3,378 Connected Watts
Office 1.8 100 180
RR .8 128 102
Storage 1 78 78
Lounge 1.8 260 468
Corridors 08 215 172
2,470 4,378 5,346

4) The service design is indicated to be existing on the Load Calcs, but new on the One Line Diagram. Please clarify.
12/11/2002 MARTIN HAEBERLE MECHANICAL-COMMERCIAL REVIEW Approved
12/11/2002 MHAEBER1 WATER REVIEW Approved
12/11/2002 MARTIN HAEBERLE PLUMBING-COMMERCIAL REVIEW Approved
12/12/2002 GERRY KOZIOL WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
12/12/2002 TAMI ACHONG OUT TO CUSTOMER Completed