Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T02CM02960
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/18/2002 | DAN CASTRO | ZONING | REVIEW | Approved | |
06/18/2002 | BLANCA ESPINO | FLOODPLAIN | REVIEW | Approved | |
06/19/2002 | JIM EGAN | FIRE | REVIEW | Approved | |
06/19/2002 | HOLLY PEARCE | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
06/20/2002 | RANDY SCHULER | ELECTRICAL-COMMERCIAL | REVIEW | Denied | GENERAL COMMENT 1) Please see the redline set for additional clarification. 2) Please return the redline set along with your next submission. E-2.1 1) The lift panels are shown as existing however Page E2.2 indicates they are new. Please clarify. E-2.2 1) The one line service diagram indicates the lift panels are new however pages E-2.1 and E-2.3 indicate the panels are existing. Please clarify. E-2.3 1) Electrical Detail 1 indicates the lift disconnects are 6" AFF. Please clarify. 2) It appears 99NEC 511-1 and 511-3 consider this application to be a Repair Garage. Please demonstrate conformance for all conduits entering into the Class I div 1 and div 2 areas. Describe conduit types and place required seals when entering or leaving each classified area. 3) The lift panels are described as existing however on page E-2.2 they are described as new. Please clarify. If the panels are new provide both component short circuit current rating and fault current analysis. 4) There are 9 portable lifts distributed between the lift panels if the loads are new provide a complete design, if they are existing please indicate same on the plan. 5) The panel schedule indicates the lift conduits are ¾" however Detail 1 and page E-2.1 indicate 1" minimum. Please clarify. 6) It appears the reference to MCC-2 to being "NEW" should be removed and the word Capacity should be added to the end of the sentence. See ELECTRICAL LOAD CALCULATIONS. 7) 99NEC 220-35 requires the peak kVA for any given month include a 25% safety margin. See ELECTRICAL LOAD CALCULATIONS. |
07/10/2002 | DHERRON1 | PLUMBING-COMMERCIAL | REVIEW | Passed | |
07/10/2002 | PIMA COUNTY | BUILDING-COMMERCIAL | REVIEW | Approved | |
07/26/2002 | GERRY KOZIOL | WWM | REVIEW | Passed | |
07/26/2002 | TACHONG1 | WATER | REVIEW | Passed |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
07/29/2002 | LISA LESNY | OUT TO CUSTOMER | Completed |