Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T02CM02896
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/19/2002 | MICHAEL ST. PAUL | ZONING | REVIEW | Passed | |
| 06/19/2002 | MICHAEL ST. PAUL | NPPO | REVIEW | Passed | |
| 06/19/2002 | MICHAEL ST. PAUL | LANDSCAPE | REVIEW | Passed | |
| 07/17/2002 | ANY | FLOODPLAIN | REVIEW | Denied | |
| 07/17/2002 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Swaim Associates 3986 E. Broadway Blvd. Attn.: Gal Winters SUBJECT: Civano Comm. School 10603 E. Mira Lane Site plan T02CM02896 (First Review) T14S, R14E, Section 2 RESUBMITTAL REQUIRED: Site Plan. The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Show existing sight visibility triangles on Night Bloom Way and Mira Lane per 2-02.2.1.10. 2. List property description on plans per 2-02.2.1.1. 3. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. 4. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance with D.S 3-01.4.4. 5. Dimension from street monument lines and right-of-way etc. per D.S. 2-02.1.19. 6. Dimensions from street monument lines to existing and proposed curbs, S/W, utilities etc. per D.S. 2-02.2.1.21. 7. New sidewalk is required along both Night Bloom Way and Mira Lane. Match existing. 8. A separate permit is required for any work done in the right-of-way, call 791-4942 for additional information. 9. Add to general notes: Depress all landscaped areas a maximum of 6" for water harvesting. 10. Show location and access of refuse container per D.S. 6-01. 11. General note 5 on sheet x1.2 refers to the Pima County Zoning code, this note should read that all work shall conform to 2000 IBC. If you have any questions, I can be reached at 791-5550 or pmachad2@ci.tucson.az.us |
| 07/17/2002 | ANY | SANITATION | REVIEW | Denied | |
| 07/18/2002 | JIM EGAN | FIRE | REVIEW | Approv-Cond | 1.FIRE APPROVAL FOR SITE ONLY. 2. FIRE HYDRANT SHALL BE INSTALLED AND IN-SERVICE BEFORE CONSTRUCTION BEGINS. 3.ON STREET PARKING IS NOT PERMITTED EXCEPT IN DESIGNATED SPACES. |
| 07/18/2002 | PATRICIA GEHLEN | HANDICAP-SITE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/31/2002 | TAMI ACHONG | OUT TO CUSTOMER | Completed |