Review Status: Completed

Review Details: SITE

Permit Number - T02CM02695
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/04/2002 JIM EGAN FIRE REVIEW Approved
06/17/2002 DAN CASTRO ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.
CODE SECTION/ DEVELOPMENT STANDARD

1. Since the site is comprised of three (3) lots, lot combination is required for this site. Attached is a copy of the covenant prepared by the City Attorney's Office, which must be recorded prior to site plan approval.
D.S. 2-02.2.1.A.2

2. Note the proposed building height. Building setback requirements may not be verified for compliance until this information is noted on the plan.
D.S. 2-02.2.1.A.6/ D.S. 2-02.2.1.A.7

3. a) The number of vehicle parking spaces shown on both present and future site plans, do not match the "provided" number noted under the vehicle parking calculation. Revise for consistency.
b) The MS&R adjustment calculation is incorrect. Note the correct adjustment calculation and ratio. The calculation requires that the vehicle parking ratio for retail (200) be added to the adjustment factor (.280), thus totaling 256. The ratio then becomes 1 parking space per 256 GFA/sq. ft.
c) Wheelstops must be located two and one-half (2½) feet in front of the parking space. Parking space detail indicates three (3).
D.S. 2-02.2.1.A.8/ D.S. 2-02.2.2.A.4/ L.U.C. 2.8.3.7
L.U.C. 3.3.4/ D.S. 3-05.2.3.C.2

4. Per L.U.C. 3.3.3.5, a minimum of two (2) bicycle parking spaces is required.
D.S. 2-02.2.1.A.9/ D.S. 2-02.2.2.A.4/ L.U.C. 3.3.3.5

5. If applicable, provide a detail of proposed freestanding signage and outdoor lighting on the site plan.
D.S. 2-02.2.1.A.13/ D.S. 2-02.2.1.A.25

6. If applicable, all existing or proposed easements must be shown on the plan including width, type, and recording docket and page reference.
D.S. 2-02.2.1.A.20

7. Note the zoning classifications of the adjacent parcels to the north and east of the subject property on the site plan.
D.S. 2-02.2.1.A.28

8. Note the existing use and proposed use as listed under L.U.C. 2.5.4.2.B.3. "General Merchandise Sales, subject to Sec. 3.5.9.2.A.
D.S. 2-02.2.1.A.31

9. Note the gross site area.
D.S. 2-02.2.2.A.1

10. Note the proposed floor area ratio.
D.S. 2-02.2.2.A.3

11. All requested changes must be made to the site and landscape plans.
D.S. 2-07.2.1.A
06/20/2002 JOE LINVILLE NPPO REVIEW Denied A Native Plant Preservation Plan is required per LUC 3.8. See DS 2-15 for plan requirements.
06/20/2002 JOE LINVILLE LANDSCAPE REVIEW Denied The loading area must be screened by a 6' masonry wall from the adjacent streets and from adjacent residential property.
LUC Table 3.7.2-I. Revise the plans to provide the required screen.

An an executed covenant for recordation stating the responsibility of the property owner, successor, or assignee
as to the removal of improvements and compliance with the LUC at no cost to the City is required for per LUC 2.8.3.5.F to comply with MS&R regulations. Copies of an acceptable document are available at the zoning review counter or online at http://www.ci.tucson.az.us/dsd/E-Services/Applications___Forms/Major_Streets_Covenant.pdf.

A 5' masonry wall is required along the north property line per LUC Table 3.7.2-I. Revise the plans to include the required wall.

Utility services and mechanical equipment must be screened per LUC Table 3.7.2-I. Revise the plan to identify any of these items and include information on appropriate screening.

The tree calculations for the interior landscape border require revision. One tree is required for every 33 feet of landscape border. The border length is roughly 150 feet on the present site. Revise the plans to provide the required number of trees.

Locate individual plants on the landscape plans. DS 2-07.2.2.A
Plants that typically grow to heights in excess of 24" should not be located within sight visibility triangles on the future plan. DS 2-06.3.8.G

City Engineer approval is required for placement of a portion of the required street landscape border within the right of way. Provide verification of the approval is required prior to Landscape Section approval of the plans. LUC 3.7.2.4
06/24/2002 BLANCA ESPINO FLOODPLAIN REVIEW Denied SEE ENGINEERING FOLDER.
06/24/2002 BLANCA ESPINO ENGINEERING REVIEW Denied Site Plan
1. Indicate lot dimensions for north and south sides of property lines. D.S. 2-02.2.1.5

2. Indicate all existing and proposed buildings and structures, height, roof slope and downspouts. D.S. 2-02.2.1.6

3. Label existing and future sight visibility triangles with appropriate lengths. D.S. 2-02.2.1.10

4. Demonstrate vehicle maneuverability for loading space area. D.S. 2-02.2.1.14

5. Indicate drainage patterns, proposed finish floor elevation(s) and finish grades. D.S. 2-02.2.1.16

6. Indicate estimated cut and fill quantities if applicable or not. D.S. 2-02.2.1.17

7. Indicate if streets are public or private. D.S. 2-02.2.1.18

8. Indicate existing and future right-of-way and widening intersection dimensions, including any applicable Major Streets and Routes (MS&R) Plan right-of-way.
D.S. 2-02.2.1.19

9. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways and utility lines. Sidewalk area for Park Ave. is 12' and for 36th St. is 11'. D.S. 2-02.2.1.21

10. Indicate refuse container location, size and access thereto fully dimensioned. Demonstrate vehicle maneuverability. D.S. 2-02.2.1.32
06/24/2002 BLANCA ESPINO SANITATION REVIEW Denied SEE ENGINEERING FOLDER.
06/27/2002 PHIL SEADER HANDICAP-SITE REVIEW Denied

Final Status

Task End Date Reviewer's Name Type of Review Description
06/27/2002 TAMI ACHONG OUT TO CUSTOMER Completed