Permit Number: T02CM02694
Parcel: 12216229B

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T02CM02694
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/05/2004 JIM EGAN FIRE REVIEW Approved
08/05/2004 PAUL MACHADO ENGINEERING REVIEW Approved
08/06/2004 Andrew Connor NPPO REVIEW Denied Included the correct species for tress on the NPP application for exception. Palo Verde is not correct, the photos are of Prosopis velutina / Native Mesquite, revise as necessary.
08/06/2004 Andrew Connor LANDSCAPE REVIEW Denied 1. The proposed loading zone must be screened from Pima Street with 6' high masonry wall on the future site plan. LUC Table 3.7.2-I. Provide any related variance cases. Submit any decision letters for any variances granted and any conditions imposed.

2. Revise keynote #5 to exclude reference to 6' masonry wall

3. The street landscape borders must a minimum of ten feet wide based on the MS&R right of way line. Temporarily the landscape border must be ten feet wide based on the street property line unless the City Engineer approves use of the right of way area for required landscaping. Provide verification of any approval to locate a portion of the 10' wide street landscape border within adjacent right of way areas.

4. A 2' separation is required between PAAL and screen wall along Alvernon Rd. per DS 3-05.2.2.B.3
An expectable substitution would be a vegetative screen.

5. Landscape plan shall include irrigation specification design and layout per DS 2-07.5.4.A & DS 2-07.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation.

6. Revise plant selection for street landscape borders Caesalpina pulcherrima and Leucophyllum frutescence will typically grow over 4'. Any plant material than thirty (30) inches must be located outside of the sight visibility triangle LUC 3.7.3.4.


7. Included the correct species for tress on the NPP application for exception. Palo Verde is not correct, the photos are of Prosopis velutina / Native Mesquite, revise as necessary.
08/30/2004 DAN CASTRO HANDICAP-SITE REVIEW Denied Accessible ramp is required to have a minimum four (4) wide ramp landing at the top of the run. ICC/ANSI A117.1-1998 Sec. 405.7
08/30/2004 Daniel Castro ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.
CODE SECTION/ DEVELOPMENT STANDARD

1. Per LUC Sec. 3.2.6.4 perimeter yard indicator "DD", a 21 foot building setback is required from the north property line to the proposed building.
D.S. 2-02.2.1.A.7/ L.U.C. 3.2.6.4

2. The rights-of-way dimensioned on both the existing and future site plans do not appear to be correct. Per the Major Streets and Routes (MS&R) plan, Alvernon Road is designated as a 120 foot MS&R r.o.w. The existing site plan shows a 60' foot half r.o.w. and the future site plan changes to a 65' ½ r.o.w. Pima Street on the other hand is designated for a 76 foot r.o.w. The existing site plan shows a 59 foot ½ r.o.w. and the future site plan changes that to a 50 foot ½ r.o.w. Please explain the discrepancy in the r.o.w. shown on both plans.
D.S. 2-02.2.1.A.8/ D.S. 2-02.2.2.A.4/ D.S. 3-05.2.2.D

3. Rectify the future curb location along Alvernon Road. MS&R face of future curb is to be located nine (9) feet (street side) from the future property line.
D.S. 2-02.2.1.A.21

4. Both existing and future site plans show a sign located in a sight visibility triangle. Per D.S. 3-01.5.1.A.1, lines of sight may not be obscured between 30 inches and six (6) feet through a triangular area adjacent to a street.
D.S. 2-02.2.1.A.13/ D.S. 3-01.5.1.A.1/ D.S. 2-02.2.1.A.25

5. Accessible ramp is required to have a minimum four (4) wide ramp landing at the top of the run. ICC/ANSI A117.1-1998 Sec. 405.7

6. Attached is a copy of the City of Tucson Major Streets and Routes Covenant, which must be signed, notarized, and recorded. Please refer to that last sheet of the covenant for additional documents needed for recordation. The covenant must be recorded prior to final site plan approval by the Zoning Review Section.

7. R.O.W. widening stamp will be placed on the existing site plan by the Zoning Review Section. This is required to advise the owner that all improvements within the future right-of-way will be required to be removed at time of road widening at no expense to the City of Tucson.

8. Since a variance will be applied for, please list the case number, date of approval, variances granted, and conditions imposed on both existing and future site plans.

9. All requested changes must be made to the site and landscape plans.
D.S. 2-07.2.1.A

If you have any questions about this transmittal, please call Dan Castro at (520) 791-5608. Be sure to include the red-lined copy site plans upon resubmittal.

Final Status

Task End Date Reviewer's Name Type of Review Description
08/30/2004 LISA LESNY OUT TO CUSTOMER Completed
08/30/2004 ANGIE SHOFFSTALL REJECT SHELF Completed