Permit Number: T02CM02218
Parcel: 111071290

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T02CM02218
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/29/2003 JIM EGAN FIRE REVIEW Approved
01/31/2003 BLANCA ESPINO FLOODPLAIN REVIEW Denied
01/31/2003 PETER MCLAUGHLIN ZONING REVIEW Denied SITE PLAN TRANSMITTAL

TO: Enrique Durazo
7475 E. Broadway Blvd. #210
Tucson, AZ 85710

FROM: Peter McLaughlin
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT:
T02CM02218
RWG Apartments
3316 E. Bermuda Street
(2nd review)

TRANSMITTAL: January 31, 2003

Upon completion of the following revisions/additions, an over the counter review may be arranged to obtain stamped approval by the zoning review section without resubmitting the site plan. The following items must be revised on or added to the site plan:


1. Revise the 2'-6" wheelstop dimension to be measured to the front side (wheel side) of the wheelstop curb.
DS 3-05.2.3.C.2

2. Revise perimeter yard setbacks on the title sheet under Code Summary to indicate that the required perimeter yard building setback is the greater of 10 feet or ¾ height of the structure wall measured from the property line.
LUC 3.2.6.4


If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
01/31/2003 PETER MCLAUGHLIN HANDICAP-SITE REVIEW Approved
02/04/2003 BLANCA ESPINO ENGINEERING REVIEW Denied Site Plan
1. The SVT's from a PAAL to a local street are 180' Near side and 110' Far side. Correct and revise.

2. The refuse container requires gates for screening and post next to the interior walls. Indicate size and access thereto fully dimensioned. Demonstrate solid waste vehicle maneuverability. Indicate a refuse container detail. D.S. 6-01.2.2, D.S. 6-01.4.1, D.S. 6-01.4.2 and D.S. 6-01.10.0 Figures 1 & 2.

3. Grading plan review required. Fill = 2,742 cu. ft.


Hydrology Report
1. This site is impacted by COT regulatory flow, as per S.M.D.D.F.M.2.3, a Hydrology Report should consist of a certain format and contents. Please re-submit a Hydrology Report consisting these items; Cover sheet 2.3.1.1, Introduction 2.3.1.2, Hydrology 2.3.1.3 & Floodplain Analyses and Results 2.3.1.4
02/07/2003 JOE LINVILLE LANDSCAPE REVIEW Denied Land Use Code Sec. 3.7.2.3.B requires a barrier, such as curbing, for trees susceptible to vehicular damage. Revise the plans to provide a suitable barrier for all tree planters and landscape areas.

Plants used to meet the screening requirements of LUC 3.7.3 are to be a minimum of five gallon size. Revise the plans as necessary. LUC 3.7.3.7.C.1

The project must be designed to comply with LUC 3.7.2.7 which requires that "All disturbed, grubbed, graded, or bladed areas not otherwise improved shall be
landscaped, reseeded, or treated with an inorganic or organic ground cover to help reduce dust pollution."
Provides notes and or specifications for ground cover.

Per LUC Table 3.7.2-I five foot high masonry walls are required wherever the parking lot is within 100 feet of the property line and the adjacent zone is residential. Revise the site and landscape plans to include the required walls.
02/07/2003 JOE LINVILLE NPPO REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
03/06/2003 MONICA VALDEZ OUT TO CUSTOMER Completed