Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T02CM02023
Parcel: 12907006S

Address:
1585 E 36TH ST

Review Status: Completed

Review Details: SITE

Permit Number - T02CM02023
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/17/2002 JIM EGAN FIRE REVIEW Denied
07/23/2002 DAVID RIVERA ZONING REVIEW Denied TO: Steve Kennedy
4450 N 12th ST. #120
Phoenix, AZ 85014
(620) 264-1955

FROM: David Rivera
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT: T02CM02023
1575 E. 36th St
New Public Library
Site Plan Review (2nd review)
TRANSMITTAL: July 23, 2002

COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.
CODE SECTION/
DEVELOPMENT
STANDARD

1. After reviewing the previous plan, phase one (Not the official approved and stamped plan) for pedestrian circulation compliance and required sidewalks from both Kino Boulevard and 36th Street to the existing development, it appears that the sidewalk from Kino was never provided. Development Standards 2-08.4.1.A requires that, at least one (1) sidewalk will be provided to a project from each street on which the project has frontage, unless there is no vehicular access from a street because of a physical barrier, such as a drainageway or an unbroken security barrier (e.g., a wall or fence). The sidewalk should be located to minimize any conflict with vehicular access to the project. A sidewalk from the Kino Boulevard right-of-way must be provided to the new library and must be interconnected with the onsite pedestrian circulation. Please show and dimension the required sidewalk.

(Previous Comment: Please delineate or define the area proposed as the continuous pedestrian circulation to the existing development.
DS 2-02.2.1.A.12

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

DGR C:\planning\DSC\T02CM02023a.doc
07/25/2002 JAMES TATE FLOODPLAIN REVIEW Approved
07/25/2002 JIM TATE ENGINEERING REVIEW Denied The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all engineering, flood plain, and solid waste comments have been addressed.

The Grading Plan was reviewed for Site Plan purposes only. A Grading Permit is required.

The following previous comments were not addressed:

1. Show, label, and dimension MS&R future right-of-way for both 36th and Kino. Intersection widening applies to 36th. See "City of Tucson Major Streets and Routes Plan Map" for future right-of-way widths. (Development Standard, DS, 2-02.2.1.A.19)

2. Show, label, and dimension the existing and future sight visibility triangles for the northwest corner of Kino and 36th. Face of future curb for Kino will be 12 ft. from future right-of-way. Face of future curb for 36th will be 11 ft. from future right-of-way.
(DS 2-02.2.1.A.10)
07/25/2002 JIM TATE SANITATION REVIEW Approved
07/25/2002 DAVE MANN HANDICAP-SITE REVIEW Approved
08/06/2002 JOE LINVILLE LANDSCAPE REVIEW Denied Revise the plans to meet the requirement for one tree for every 33 feet of the street landscape borders. LUC Sec. 3.7.2.4
08/06/2002 JOE LINVILLE NPPO REVIEW Denied Submit NPPO Plan or application for exception. LUC 3.8. Copies of any previously approved NPPO plans may be acceptable if applicable to the site. Applications or plans must accompany the site plan submittal. Resubmittal will not be accepted without required NPPO information. See the Landscape Section for OK to submit.

Final Status

Task End Date Reviewer's Name Type of Review Description
08/30/2002 TAMI ACHONG OUT TO CUSTOMER Completed