Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T02CM02001
Parcel: 107060280

Review Status: Completed

Review Details: SITE

Permit Number - T02CM02001
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/03/2002 DAN CASTRO ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.
CODE SECTION/ DEVELOPMENT STANDARD

1. This review is based on a site area expansion of 24.7% resulting in a full code compliance review for the expansion only. Please provide a copy of the last approved site plan for the property west of this site. The site plan is needed to verify that the portion of land being used for this addition was not required to meet L.U.C. requirements for the site west of the subject property.

2. The legal description for the reconfigured lot must be recorded and proof of recordation must be submitted to the Zoning Review Section prior to site plan approval.
D.S. 2-02.2.1.A.2

3. a) Note the building height of the office addition and carport on the plan.
b) Revise the building area calculations to reflect the office addition only.
D.S. 2-02.2.1.A.6

4. Revise the vehicle parking calculations to reflect the correct storage area for this site.
D.S. 2-02.2.1.A.8/ L.U.C. 3.3.4

5. Bicycle parking is not required for the office and carport addition. Revise bicycle parking calculation requirement. If a bicycle parking space is provided, please add a fully dimensioned detail on the plan. Refer to D.S. 2-09 for design criteria.
D.S. 2-02.2.1A.9/ L.U.C. 3.3.4/ D.S. 2-09

6. Dimension the point of ingress/egress on the plan.
D.S. 2-02.2.1.A.11

7. a) Label and dimension loading zones on the plan. Last approved site plan indicates two (2) loading zones on the east side of the existing buildings.
b) Per L.U.C. 3.4.5.2, one (1) 12' x 55' loading space is required for the overall site. Please add a note, which states the number of loading spaces required and provided.
D.S. 2-02.2.1.A.14/ D.S. 2-02.2.2.A.5/ L.U.C. 3.4.5.2

8. Label and dimension existing and future right-of-way for El Burrito Avenue.
D.S. 2-02.2.1.A.19

9. If applicable, all existing or proposed easements must be shown on the plan including width, type, and recording docket and page reference.
D.S. 2-02.2.1.A.20

10. Dimension distance from property line to existing curb along El Burrito Avenue.
D.S. 2-02.2.1.A.21

11. Add the floor area ratio calculation on the plan.
D.S. 2-02.2.2.A.3

12. Delete the old zoning classification B2A under the zoning block on the cover sheet.
07/05/2002 JIM EGAN FIRE REVIEW Denied
07/24/2002 JOE LINVILLE NPPO REVIEW Approved Exception. Previously developed site per approved site plan.
07/24/2002 JOE LINVILLE LANDSCAPE REVIEW Denied New development or uses on the site are subject to LUC 3.7.
Existing approved development on the site is subject to the zoning regulations in effect at the time the site was last approved for zoning compliance. LUC 3.7.1.2 Relocation of required elements are also subject the site to review. Provide a copy of the approved landscape plan.

Provide approved and or revised landscape plans for the site. DS 2-07.2.0

The proposed site plan differs from the plan approved in 1984 as follows. The required landscape and screening is not indicated on the new plan, the refuse storage area is in a new location, the loading areas area in a new location, there are new storage yards indicated on the revised plan. Revise the plan to include required landscape elements and to provide screening per LUC 3.7.2-I & LUC 3.7.3.
07/29/2002 BLANCA ESPINO SANITATION REVIEW Approved
07/29/2002 BLANCA ESPINO ENGINEERING REVIEW Denied Site Plan
1. Indicate lot bearings along with dimensions. D.S. 2-02.2.1.5

2. Indicate drainage flow patterns. D.S. 2-02.2.1.16

3. Indicate estimated cut and fill quantities if applicable or not. D.S. 2-02.2.1.17
07/29/2002 BLANCA ESPINO FLOODPLAIN REVIEW Denied SEE ENGINEERING FOLDER

Final Status

Task End Date Reviewer's Name Type of Review Description
07/31/2002 MONICA VALDEZ OUT TO CUSTOMER Completed