Review Date Reviewer's Name Type of Review Description Status Comments
02/27/2003 DAN CASTRO ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.
CODE SECTION/ DEVELOPMENT STANDARD

1. Dimension the width of the one-way PAAL.
D.S. 2-02.2.1.A.11

2. a) Provide a fully dimensioned bicycle parking space detail. Refer to D.S. 2-09 for design and location criteria.
D.S. 2-02.2.1.A.9/ D.S. 2-09

3. Note the LDO case number, date of approval, and conditions imposed on the site plan.
D.S. 2-02.2.1.A.38

4. Review of this plan by the Zoning Review Section may be done over the counter. Please contact Dan Castro to set an appointment.
03/10/2003 JOE LINVILLE NPPO REVIEW Approved exception per 1998 PC aerial photo.
03/10/2003 JOE LINVILLE LANDSCAPE REVIEW Denied The 3'5' patio wall shown in front of the Brighton Lane landscape border(adj. to Unit 2) conflicts with LUC 3.7.3.2.B which states "screens along a street frontage must be located on the development side of the street landscape border so that they do not obstruct the view of the street
landscape border from the street." The wall shown does not comply.

Expansions to the vehicular use/parking areas on the site must be landscaped, including street landscape borders. The border along Hart Lane must be a minimum of ten feet wide. LUC 3.7.2.4.

New parking areas must be screened with a 5' masonry wall from adjacent properties. LUC Table 3.7.2-I
Revise the plans to provide masonry wall screening of the new parking area from the residences to the north and south. LUC Table 3.7.2-I

Dust control material, such as decomposed granite, is required for the new landscape borders. LUC 3.7.2.7
03/17/2003 ANY ENGINEERING REVIEW Denied To: Blue Denim, Inc.
5461 W. Idle Hour Place
SUBJECT: 5729 E. Pima Street
Site plan T02CM01904 (Second Review)
T14S, R14E, Section 1

RESUBMITTAL REQUIRED: Site Plan.

The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Re-label or add the title " Civil Site Plan" to either of the site plans or remove the word "Zoning" since one site plan for both is sufficient.
2. Dimension the ingress/egress lanes and provide/show vehicle maneuverability.
3. Obtain approval from Solid waste for the possible need of an additional refuse container or not.
4. Show existing sight visibility triangles on Hart Lane.
5. Please show point of access (driveway apron or curb radii) per D.S. 2-02.2.1.11.
6. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16.
7. A DSMR request is required for any construction in the future sight visibility triangle. The wooden fence cannot be more than 30" tall in the SVT.
8. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance with D.S 3-01.4.4.
9. Dimension from street monument lines and right-of-way etc. per D.S. 2-02.1.19. Per pervious comment.
10. Dimensions from street monument lines to existing and proposed curbs, S/W, utilities etc. per D.S. 2-02.2.1.21. Per pervious comment.
11. Show intermittent spot elevations per D.S. 2-01.2.1.23.
12. A separate permit is required for any work done in the right-of-way, call 791-4942 for additional information.

If you have any questions, I can be reached at 791-5550 x1193 or pmachad2@ci.tucson.az.us
Paul Machado
Senior Engineering Associate
03/17/2003 ANY ENGINEERING REVIEW Denied Please include a response letter along with your corrections.
03/18/2003 ANY SANITATION REVIEW Denied
03/18/2003 ANY FLOODPLAIN REVIEW Approved See engineering folder.

Final Status

Task End Date Reviewer's Name Type of Review Description
04/10/2003 TAMI ACHONG OUT TO CUSTOMER Completed