Permit Number: T02CM01805
Parcel: 13109192A

Address:
5639 E 28TH ST

Review Status: Completed

Review Details: SITE

Permit Number - T02CM01805
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/27/2002 PETER MCLAUGHLIN ZONING REVIEW Denied TO: Laurie Fitzgerald
4701 E. Winged Foot Drive
Tucson, AZ 85718
615-9070 & 235-2976

FROM: Peter McLaughlin
Senior Planner
Development Services Dept.
FOR: Patricia Gehlen
Principal Planner
Development Services Dept.
PROJECT:
T02CM01805
New Duplex
5637 - 5641 E. 28th Street
Tucson, AZ 85711
Site Plan Review (2nd review)

TRANSMITTAL: June 27, 2002

Upon completion of the following revision/addition, an over the counter review may be arranged to obtain stamped approval by the zoning review section without resubmitting the site plan. The following item must be revised on or added to the site plan:

1. As noted, because the previously approved site plan does not show the existing carport and as noted in your response comments, an LDO will be required for the east property line building setback to the carport. Show the connection of the carport on the site plan as was done for the detail drawing, and indicate with a label that the roof connection will be able to support fifty (50) pounds of weight.
DS 2-02.A.2.1.38, LUC 3.2.6.4

2. Some of the dimensions shown on the site plan are not consistent with those in the detail. For example, the east lot line building setback to the carport is stated to be 4'-10" on the site plan and 5 feet on the detail. Also, the distance between the sidewalk along 28th Street and the wall reads 6'-4" on the detail and 6'-11" on the site plan. Note: the 6'-11" dimension is placed in the wrong location on the site plan drawing. Please revise and make sure all dimensions are consistent on both drawings.

3. The sight visibility triangles are not drawn correctly. The stem side of the triangles must measure twenty (20) feet. They scale to only approximately ten (10) feet on the detail drawing. Please revise and dimension stem and street-facing sides of SVT's.
DS 2-02.A.2.1.10

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
07/17/2002 JOE LINVILLE LANDSCAPE REVIEW Denied Plans approved for zoning compliance in 1979 indicate a 5' landscape border on site and a 30" screen wall along 28th street. Revise the site plan to include these items. The 4' wall indicated on the proposed site plan conflicts with sight visibility requirements and must be revised.
07/30/2002 ANY SANITATION REVIEW Denied
07/30/2002 PAUL MACHADO ENGINEERING REVIEW Denied To: Matthew Hodeaux Architect
SUBJECT: 5637-5641 E. 28th Street
Site plan T02CM01805 (Second Review)
T14S, R14E, Section 28

RESUBMITTAL REQUIRED: Site Plan

The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.



Site Plan:

1. Show existing and if applicable future sight visibility triangles on 28th Street per 2-02.2.1.5 and 3-01.5.0., also see redlines.
2. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes on the site plan. The response to the previous comment is a note of "slopes no to exceed 2%" was added to the survey? This is acceptable, except I can't find it on the survey. Perhaps the note should also be placed on the site plan. Please revise.
3. Please provide a letter from solid waste management for permission on curbside service, I am currently waiting on a response from Rene Duarte.



If you have any questions, I can be reached at 791-5550 or pmachad2@ci.tucson.az.us
07/30/2002 ANY FLOODPLAIN REVIEW Denied

Final Status

Task End Date Reviewer's Name Type of Review Description
08/06/2002 LISA LESNY OUT TO CUSTOMER Completed