Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T02CM01515
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/27/2002 | JIM EGAN | FIRE | REVIEW | Approved | |
| 04/04/2002 | PETER MCLAUGHLIN | ZONING | REVIEW | Approved | TO: Attn: Chris Staag FROM: Peter McLaughlin 900 S. Randolph Way Senior Planner Tucson, Arizona 85716 PROJECT: T02CM01515 Campfire USA Skatepark 401 East 22nd Street Tucson, Arizona TRANSMITTAL: April 4, 2002 DUE DATE: April 3, 2002 COMMENTS 1. Since no new buildings are proposed, this site plan is being reviewed as a less than 25 % expansion. Please provide a copy of the last approved site plan with the next submittal. 2. Please provide the current zoning for the site and adjacent properties on the plan. The zoning on the entire site is R-2. DS 2-02.2.1.A.28 3. Provide the square footage of the skate park and add vehicular and bicycle parking calcs to site plan. The proposed skate park requires one vehicle parking space per 1,000 square feet of skate park area. An administrative waiver may be applied for if the required on-site parking is not provided. If new parking is proposed, the spaces must be shown on the site plan, fully dimensioned. DS2-02.2.1.A.8, DS 2-02.2.2.A.4 4. Please provide a fully dimensioned layout of any new bicycle parking proposed. Also, include the specific type of rack and the number of bicycles it supports. DS 2-02.2.1.A.9, DS 2-09.6.0 5. Please detail any proposed freestanding lighting layout on the site plan. Keynote 6 indicates skate park lighting but it is not found on the drawing. DS 2-02.2.1.25 6. The location, type, size and height of all proposed freestanding signage must be shown. DS 2-02.2.1.A.13 7. Provide a small plan which shows the entire park property and the location of the proposed skate park within the park for reference. DS 2-02.2.1.A.5 8. Add a general note which states that no new buildings are proposed. DS 2-02.2.1.A.6 9. Add a note which states that no loading zones are required. DS 2-02.2.2.A.5 10. If an administrative waiver is obtained, date of approval and waivers granted must be added to site plan. DS2-02.21.2.1.A.38 11. Provide general notes demonstrating compliance with the restrictions detailed in 3.5.13.2 (hours of operation) and 3.5.13.3 (outdoor lighting). LUC 2.3.5.2.E.1 12. Remove the approval signature lines from the cover sheet. 13. Provide the project address and legal description for the site. DS 2-02.2.1.A.2 & A.3 14. Connection between the skate park and the on-site pedestrian circulation is required. 15. Add the development designator "12" to general notes. |
| 04/09/2002 | DOUG WILLIAMS | NPPO | REVIEW | Approved | |
| 04/09/2002 | DOUG WILLIAMS | LANDSCAPE | REVIEW | Approved | |
| 05/07/2002 | BLANCA ESPINO | FLOODPLAIN | REVIEW | Denied | |
| 05/07/2002 | BLANCA ESPINO | ENGINEERING | REVIEW | Denied | |
| 05/07/2002 | BLANCA ESPINO | SANITATION | REVIEW | Denied | |
| 05/08/2002 | DAVE MANN | HANDICAP-SITE | REVIEW | Approv-Cond |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/05/2002 | TAMI ACHONG | OUT TO CUSTOMER | Completed |