Permit Number: T02CM01282
Parcel: 132191160

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T02CM01282
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/06/2002 DAN CASTRO ZONING REVIEW Approved
03/06/2002 DOUG WILLIAMS FLOODPLAIN REVIEW Approved
03/07/2002 JIM EGAN FIRE REVIEW Approved
03/08/2002 HOLLY PEARCE PLUMBING-COMMERCIAL REVIEW Denied Plumbing 1. Waste line isometric drawing does not comply with Sec 901.0,905.3,1011.3 UPC1994 Az. Code- provide a clean out down stream of the grease trap. 2. Part of the 3-comp sink shall be direct waste. 3.Provide clean outs per Sec 707.0 UPC 1994 Az. Code. 4. Provide the total demand length of gas line on the plan. Provide a fire system valve on the gas line serving the cooking equipment. ( see yellow tabs on bluelines) 5. Provide a water demand calculation based on Appendix A UPC 1994 Az. Code, on the plan. 6. Combustion air and relief air for the W.H. shall comply with Sec507.3.1 (c) UPC 1994 Az. Code.
03/08/2002 HOLLY PEARCE MECHANICAL-COMMERCIAL REVIEW Denied Mechanical 1. Architect of record shall provide a complete detail of the one hour ceiling required above the type-I hood and 18 inches around all sides. 2. Kitchen exaust does not comply with Sec 506.3.13.3 IMC 2000. 3. Provide access to equipment on the roof per Sec 306.5 IMC 2000. 4. Show on the plan how the mechanical design complies with Chapter 4 IMC 2000.
03/12/2002 RANDY SCHULER ELECTRICAL-COMMERCIAL REVIEW Approved
03/18/2002 DOUG LAAKSO BUILDING-COMMERCIAL REVIEW Denied SEE COMMENTS ATTACHED TO APPLICATION.
03/19/2002 INGA DAVIDSON WATER REVIEW Approv-Cond
03/21/2002 GERRY KOZIOL WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
03/22/2002 DELMA ROBEY OUT TO CUSTOMER Completed