Permit Review Detail
Review Status: Stopped
Review Details: SITE
Permit Number - T02CM00928
Review Name: SITE
Review Status: Stopped
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/19/2002 | JIM EGAN | FIRE | REVIEW | Denied | SHOW LOCATION OF EXISTING FIRE HYDRANTS ON PLAN. |
| 02/27/2002 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. CODE SECTION/ DEVELOPMENT STANDARD 1. a) Legal description of this site must be listed on the plan. b) Lot combination is required for this site. Attached is a copy of the covenant prepared by the City Attorney's Office which must be recorded prior to site plan approval. D.S. 2-02.2.1.A.2 2. Note the project address on the plan. D.S. 2-02.2.1.A.3 3. What is the proposed use of the 16,702 square foot lot west of the Walgreens? Will this become a separate lot for future development? Additional comments may be forthcoming upon resubmittal. 4. Note the proposed building height and maximum allowed building height (40') on the plan. Building setbacks may not be verified until this information is provided. 5. Where applicable, please enlarge letters and numbers to minimum font size of 12. 6. a) Compact parking spaces are only allowed in the Downtown Redevelopment District. Please revise spaces to a minimum width of 8½ feet width by 18 feet length. b) Wheelstops or post barricades are required to prevent parked vehicles from damaging adjacent landscaping and walls. Refer to D.S. 3-05.2.3.C for additional information. c) Clearly delineate drive-through lanes on plan. In addition, label and dimension drive-through lanes and vehicle stacking spaces. Refer to D.S. 3-05.2.1.C.2 for requirements. D.S. 2-02.2.1.A.8 L.U.C. 3.3.7.2.C.1 D.S. 3-05.2.3.C D.S. 3-05.2.1.C.2 7. a) Provide bicycle parking calculation which includes the number and type of bicycle parking spaces required and provided. Refer to LUC 3.3.4. for number required. b) Provide a fully dimensioned bicycle parking detail. Refer to D.S. 2-09 for design criteria. c) Since bicycle parking is located behind the store, directional signage from Speedway Blvd. is required. D.S. 2-02.2.1.A.9 L.U.C. 3.3.4 D.S. 2-09 8. Label and dimension exiting and future right-of-way for Speedway Blvd. and First Street. Per the Major Streets and Routes (MS&R) Plan, future right-of-way for Speedway Blvd is 120 feet. Sight visibility triangles and future curb location may not be verified for compliance until this information is provided. D.S. 2-02.2.1.A.10 D.S. 2-02.2.1.A.19 9. Is ingress/egress proposed from First Street? Dimension width of ingress/egress. D.S. 2-02.2.1.A.11 10. a) Provide continuous on-site pedestrian circulation to First Street right-of-way. b) Pedestrian path located between vehicle parking spaces must be raised concrete sidewalk. Striped pedestrian path is only allowed when crossing a PAAL. c) Dimension sidewalk width. Minimum required is four (4) feet. D.S. 2-02.2.1.A.12 D.S. 2-08 11. Label and dimension existing and future curb location along Speedway Blvd and First Street. Refer to above comment number eight (8) for additional criteria. D.S. 2-02.2.1.A.21 12. Delineate zoning boundaries south of the site. Zoning maps indicate R-3 zoning and C-1 zoning south of the subject property. Contact the Planning Department Drafting Section (791-4541) for information regarding zoning boundary locations. D.S. 2-02.2.1.A.28 13. a) Add the existing use of the site as a general note. b) Add the following general note: Proposed use is General Merchandise Sales, Development Designator 31, "subject to" LUC 3.5.9.2.A. D.S. 2-02.2.1.A.31 14.All requested changes must be made to the site and landscape plans. D.S. 2-07.2.1.A |
| 03/12/2002 | JOE LINVILLE | NPPO | REVIEW | Denied | Submit a native plant preservation plan or application for exception. Landscape note 4 on Sheet L1 indicates that the project requires a pre-permit inspection. Is this related to protected native plants? LUC 3.8 |
| 03/12/2002 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | Dimension all adjacent right-of-way areas, including any applicable Major Streets and Routes (MS&R) Plan right-of-way on the site plan. DS 2-02-2.1.19 Required landscape borders must be located based on the MS&R right of way line, when applicable, or on the property line along non-MS&R streets. A street landscape border per LUC Sec 3.7.2.4. is required along the First Street frontage. Revise the landscape plan to provide all of the required elements. Provide calculations per DS 2-07.2.2.A.2. The border is required along the entire street frontage with the exception of the ingress egress location. The width of the ingress/egress area proposed may not exceed the maximum allowed by the Engineering Section. Revise the landscape plan to include water harvesting areas. LUC Sec. 3.7.4.3 All disturbed areas of the site and adjacent right of way areas, if not developed or landscaped must be treated with an appropriate inorganic material. LUC Sec. 3.7.2.7 & 3.7.2.4.A.3 Add notes or specifications as necessary. Add the legal description to the landscape plan. DS 2-07 A minimum 5' screen is required along the entire length of the First street border(except where greater heights or more substantive materials are required), and a 30" screen is required along Speedway. The screening along Speedway must extend to fully screen the vehicular use area. LUC 3.7.3, Table 3.7.2-I Revise the irrigation plan to include elements required for the Speedway Boulevard border. DS 2-07.7.7.A.3 A 6' minimum masonry wall is required to completely screen the refuse storage from First Street. A 6' screen wall is required to screen the entire loading area. LUC Table 3.7.2-I Add LUC 3.7.6 as a general noten to the landscape plan. |
| 03/15/2002 | LAITH ALSHAMI | FLOODPLAIN | REVIEW | Denied | |
| 03/15/2002 | LAITH ALSHAMI | ENGINEERING | REVIEW | Denied | Laith Alshami, 03/15/2002. FLP and Eng comments: 1- Correct the sight visibility triangles according to the requirements of Development Standard 3-01.5.1.B and 3-01.5.3. 2- Dimension the right of way, including any applicable Major Streets and Routs Plan right of way (D.S. 2-02.2.1.19). Include existing and future if applicable. 3- Provide lot dimensions and bearings (for all lot lines) (D.S. 2-02.2.1.5). 4- Show existing topographic contours according to Development Standard 2-02.2.1.23. Spot elevations will suffies. Additionally, show proposed elevations including Walgreens structure finished floor elevation. 5- Show roof drainage and provide for 10-year roof runoff conveyance under the sidewalks (D.S 3-01.4.4.F) 6- Show the correct store number in the title block. 7- The drainage statement is acceptable for this site plan purposes. |
| 03/15/2002 | LAITH ALSHAMI | SANITATION | REVIEW | Approved | |
| 03/15/2002 | PHIL SEADER | HANDICAP-SITE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/15/2002 | ELAINE ROSE | OUT TO CUSTOMER | Stop |