Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Permit Number - T02CM00893
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/08/2002 | PETER MCLAUGHLIN | ZONING | REVIEW | Approved | |
| 07/08/2002 | PETER MCLAUGHLIN | NPPO | REVIEW | Passed | |
| 07/30/2002 | JAMES TATE | FLOODPLAIN | REVIEW | Denied | Given to Jim Tate on 7/26. Previously w/ MWF. |
| 07/30/2002 | JIM TATE | SANITATION | REVIEW | Denied | Obtain written permission from Solid Waste for curbside pickup for each lot. |
| 07/30/2002 | JAMES TATE | FLOODPLAIN | REVIEW | Denied | Show drainage patterns, finish floor elevations, and finsih grades for each lot. Per the Flood Use Permit finish floor elevations must be 2 ft. above gighest existing adjacent grade. Include a note on the plan that the property is in Fema Special Flood Hazard Area AO with average flood depths of one foot. See Engineering folder for a complete list of comments. |
| 07/30/2002 | JIM TATE | ENGINEERING | REVIEW | Denied | The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. 1. Show drainage patterns, finish floor elevations, and finish grades for each lot. DS 2-02.2.1.A.16 2. Fills in excess of 2 ft. above existing grade within 100 ft. of residentially zoned areas require the procedure specified in IBC Chapter 36, Section 13.1. Provide sufficient grade information to show that fills are not in excess of 2 ft. or perform the above mentioned procedure for each lot. 3. Obtain written permission from Solid Waste for curbside pickup for each lot. 4. Per the Flood Use Permit finish floor elevations must be 2 ft. above highest existing adjacent grade. 5. Include cut and fill quantities on the plan for each lot. DS 2-02.2.1.A.17 6. A Grading Permit is required if either: (IBC Chapter 36, Section 6.2) 1. There are fills greater than 50 yds. on any lot or 2. There are fills greater than 1 ft. with a slope greater than 20%. 7. The information provided with the above comments will determine whether or not a Grading Permit is required. 8. Show existing topographic contours at intervals not exceeding two feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number. 9. Include a note on the plan that the property is in Fema Special Flood Hazard Area AO with average flood depths of one foot. |
| 07/31/2002 | MVALDEZ1 | BUILDING-RESIDENTIAL | REVIEW | Needs Review | |
| 07/31/2002 | MVALDEZ1 | WWM | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/31/2002 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |