Review Date Reviewer's Name Type of Review Description Status Comments
02/12/2002 BLANCA ESPINO FLOODPLAIN REVIEW Approved
02/13/2002 DAVE WITT BUILDING-RESIDENTIAL REVIEW Approved 1. R602.10.1 The 48'' width of braced wall panels can be
reduced to not less than 2''-8'' if 1800 lb. holddowns are
used. They are required at all four corners.
2. Brick veneer ( Front South Elevation ) Provide details for
support , anchorage , air space , and weather proofing.
See R703.7 .
02/13/2002 DAVID RIVERA NPPO REVIEW Passed
02/13/2002 DAVID RIVERA ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
02/28/2002 MONICA VALDEZ OUT TO CUSTOMER Completed