Permit Number: T02CM00575
Parcel: 13609085A

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T02CM00575
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/26/2002 TERRY STEVENS BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T02CM00575
02/21/02 2ND REVIEW 03/26/02
PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

GENERAL REQUIREMENTS:

1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

STRUCTURAL PLANS:

1. MIN. REQUIRED SLOPE FOR ROOFS WITH CLAY TILE IS 21/2" PER FOOT. INDICATED PORCHES DO NOT APPEAR TO MEET THIS REQUIREMENT. ------THIS HAS NOTHING TO DO WITH THE FRAMING MEMBERS

2. NOTE AND SPECIFY ALL ROOF SLOPES APPROPRIATE TO MATERIAL (SEE R905).

MECHANICAL PLANS:

1. INDICATE SIZE OF SUPPLY AND RETURN AIR DUCTS

ELECTRICAL PLANS:

1. INDICATE SIZE OF FEEDERS TO SUBPANEL

2. SUBPANEL LOCATED IN CLOSET DOES NOT APPEAR TO MEET REQUIRED 30" SIDE CLEARANCES NOR 36" FRONT CLEARANCE
A SUBPANEL CANNOT BE LOCATED IN A CLOTHES CLOSET
LOCATIONS OF A SUBPANEL CANNOT BE OPTIONAL


IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
TERRY STEVENS @ 791-5550 EXT. 112