01/30/2002 | JIM EGAN | FIRE | REVIEW | Approved | |
02/12/2002 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. CODE SECTION/ DEVELOPMENT STANDARD 1. Note the legal description of the property. D.S. 2-02.2.1.A.2 2. Add lot dimensions and bearings. D.S. 2-02.2.1.A.5 3. a) The number of vehicle, bicycle, and loading spaces required may not be verified for compliance until verification from the Planning Department stating that the variance(s) approved for the previous expansion in 1999 will be allowed for this expansion. Please contact Wayne Bogdan at the Planning Department (791-4541) for information regarding the variance. Provide copy of the Board of Adjustment Variance (C10-99-04) approval letter with resubmittal. b) Provide a fully dimensioned typical bicycle parking detail for both class I and Class II parking spaces. Refer to D.S. 2-09 for design criteria. D.S. 2-02.2.1.A.8/ D.S. 2-02.2.1.A.9/ D.S. 2-09 4. Label and dimension existing and future sight visibility triangles along Wrightstown Road. D.S. 2-02.2.1.A.10 5. Provide continuous on-site pedestrian circulation from new retail buildings to existing on-site buildings and Wrightstown Road right-of-way. Refer to D.S. 2-08 for requirements. D.S. 2-02.2.1.A.12/ D.S. 2-08 6. If applicable, provide a detail of existing and/or proposed free standing signage and outdoor lighting on the site plan. D.S. 2-02.2.1.A.13/ D.S. 2-02.2.1.A.25 7. a)The number of loading spaces required may not be verified for compliance until the Board of Adjustment Variance approval letter for case C10-99-04 is verified. See above comment number 3a. b) Per L.U.C. 3.4.5.3, one (1) 12' x 35' loading spaces is required for retail building one (1). D.S. 2-02.2.1.A.14/ D.S. 2-02.2.2.A.5/ L.U.C. 3.4.5.3 8. Label and dimension future curb location along Wrightstown Road. D.S. 2-02.2.1.A.21 9. If applicable, all existing or proposed easements must be shown on the plan including width, type, and recording docket and page reference. D.S. 2-02.2.1.A.20 10. All requested changes must be made to the site and landscape plans. D.S. 2-07.2.1.A |
02/14/2002 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | Submit the previously approved landscape plan applicable to the site. |
02/15/2002 | JOE LINVILLE | NPPO | REVIEW | Approved | |
02/25/2002 | ANY | ENGINEERING | REVIEW | Denied | 1. Please show the future and existing sight visibility at both of the ingress/egress on Wrightstown on the plan per D.S. 2-02.1.10. 2. The Paving, Grading, Utility plan and the drainage statement were reviewed for site plan purposes only. A separate submittal is required for a grading permit. 3. Correct the scale to an engineering units, i.e. 1"=40'. 4. Show the percentage of cross slopes of the P.A.A.L. A typical cross section would suffice. 5. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance per D.S. 3-01.4.4.F. 6. Any work done in the public right-of-way will require a permit. Call 791-4942 for permit requirements. 7. List estimated cut and fill quantities per 2-02.1.1.17. 8. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways and utility lines per D.S. 2-02.1.21. 9. Please note that most of the information on the approved site plan. This is to ensure proper and accurate record keeping. 10. Show Drainage flow arrows and the proposed FFE and spot elevations on the plans per D.S. 2-02.1.16. 11. Show existing contours or spot elevations and benchmark per 2-02.1.23. 12. Please show property description per 2-02.2.1.1. 13. Show lot dimensions and bearings per D.S. 2-02.1.5. 14. The refuse container locations are acceptable, however it appears the maneuvering radii may be to small please list the radii on the plans per 2-02.1.32 and 6-01.0.0. 14. Show the loading space for Building #1 per 2-02.1.14. |
02/25/2002 | ANY | FLOODPLAIN | REVIEW | Denied | |
02/25/2002 | ANY | SANITATION | REVIEW | Denied | |
02/27/2002 | PHIL SEADER | HANDICAP-SITE | REVIEW | Denied |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
02/28/2002 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |