Permit Number: T02CM00413
Parcel: 11931019K

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM

Permit Number - T02CM00413
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/25/2002 DAN CASTRO ZONING REVIEW Approved
01/25/2002 DOUG WILLIAMS FLOODPLAIN REVIEW Approved
02/04/2002 JOE LINVILLE NPPO REVIEW Denied A Native Plant Preservation Plan is required per LUC 3.8 and DS 2-15. The permit will not be approved without approval of the required plan.
Add the following note to the plan: A Native Plant Preservation Pre-Permit Inspection is required prior to any site work. Call 791-5550 Ext. 140 to schedule.

The following Hillside Developent Standards apply to the project; revise the plans and add notes in accordance with the standards. DS 9-06.0

The portions of the site or lot to be graded will be clearly shown by the developer's engineer or land surveyor, both on a site or grading plan and by staking on the site or lot.

If natural areas are designated on a site or lot, temporary
fencing will be installed where they abut construction areas in order to prevent encroachment into the natural areas.

Exposed cut and fill slopes will either be revegetated or protected by constructed means, such as riprapping or retaining walls.

Revegetation. All cut or fill slopes which are no steeper than three horizontal to one vertical (3:1) and all utility trenches or septic leaching fields which are not located in parking or driveway areas will be revegetated in compliance with the
following requirements.

All plants used in revegetation must be the same as the native vegetation on the site or any adjacent site prior to grading or clearing.

Revegetation will be accomplished with the following minimum requirements for plants.

a. Desert trees, a minimum of fifteen (15) gallon size with a minimum trunk diameter of two (2) inches measured at the soil level, or large specimen cactus will be placed at the same vegetation density found on the site prior to any clearing, grubbing, or grading.

b. Seeds for trees, desert shrubs, and grasses will be planted with a density adequate to control erosion and may use one of the following methods of planting or any other method approved by the Zoning Review Section at DSD.
1) Raked into the soil with appropriate mulch materials;
2) Hydroseeding;
3) Anchored mulches; or
4) Established on jute, rolled straw, or similar material.

3. A temporary watering system must be installed until the revegetation materials are established.

Slope Stabilization. All slopes steeper than a ratio of three horizontal to one vertical (3:1), with the exception of retaining walls, will be stabilized with properly engineered stone riprapping or sculptured rock as follows.

A. Stone riprapping will be hand-placed on the slope.

B. The stabilizing material used will blend with the natural appearance of the site or lot and the surrounding terrain.

C. Vegetation retention and revegetation should be used in conjunction with riprapping.
02/05/2002 LLESNY1 BUILDING-RESIDENTIAL REVIEW Needs Review
02/11/2002 GERRY KOZIOL WWM REVIEW Denied

Final Status

Task End Date Reviewer's Name Type of Review Description
02/26/2002 MONICA VALDEZ OUT TO CUSTOMER Completed