| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/14/2002 | PETER MCLAUGHLIN | ZONING | REVIEW | Approved | |
| 01/14/2002 | PETER MCLAUGHLIN | NPPO | REVIEW | Passed | |
| 01/14/2002 | BLANCA ESPINO | FLOODPLAIN | REVIEW | Approved | |
| 01/18/2002 | REYES ARVAYO | BUILDING-RESIDENTIAL | REVIEW | Denied | 2000 IRC RESIDENTIAL CHECKLIST Date: 01-17-02- Re: Project No. T01CM00208 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. SCOPE OF REVIEW: The scope of this review covers Architectural, Structural, Plumbing, Mechanical, Model Energy and Electrical codes. All code references are to the 2000 IRC. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. SITE PLAN: 1. Indicate the location of gas, water, and sewer lines on the property, and where they enter the building. Provide the location of your water and gas meter. PLUMBING PLANS: 1. Gas: Provide the length of line to each appliance, BTU demand of each appliance, size of each branch, total demand and developed length . See G2412 and Tables G2412.3(1) through G2412.3(6). REVIEWED REYES ARVAYO 791-5550 EXT, 110 |
| 01/25/2002 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/30/2002 | LLESNY1 | OUT TO CUSTOMER | Completed |